Loute G, Adam A, Ers P, Heremans C, Willems B
Eur J Clin Pharmacol. 1986;31 Suppl:53-5. doi: 10.1007/BF00541468.
The concentration of Torasemide in plasma, dialysate and ultrafiltrate were determined during one haemofiltration and three dialyses. Results show that Torasemide is not significantly eliminated from the blood by these technics.
在一次血液滤过和三次透析过程中,测定了血浆、透析液和超滤液中托拉塞米的浓度。结果表明,这些技术并未使托拉塞米从血液中显著清除。