Abstract

BACKGROUND

Craniovertebral angle (CVA) alteration is a causative factor for the neck, shoulder, and temporomandibular joints disorders. Therefore, as an outcome measure for therapeutic intervention, measuring the craniovertebral angle with the Surgimap smartphone app is a cost-effective, easily accessible, and reliable tool. This study's objective was to assess the clinimetric properties of the Surgimap smartphone application with Surgimap system software to measure the Craniovertebral Angle in different age groups and positions.

METHOD

Ninety subjects with neck pain were randomly allocated to aged between 18 and 30 years (Group A; n = 45) and 45-60 years (Group B; n = 45). Using the Surgimap smartphone application and Surgimap system software, the craniovertebral angle was measured objectively in the sagittal plane. Intraclass correlation coefficients were used to determine validity and reliability. Receiver operating characteristic (ROC) curves and the area under the curves (AUC) were determined to distinguish participants with and without forward head posture.

RESULT

The result of this study shows that Smartphone Surgimap Application and Surgimap System Software correlate 0.95 and have p-values of 0.01 for diverse positions and ages. CVA measurement in the sitting position was significantly lower than in the standing position, regardless of methodology or age. Both positions demonstrated high intra-rater reliability, as evidenced by Intraclass Correlation Coefficients (ICC) between 0.972 and 0.991. The minimum detectable change (MDC) values ranged from 1.3 to 1.733, indicating high measurement accuracy. The smartphone application demonstrated outstanding diagnostic sensitivity (100.00% for Group A standing) and specificity (93.55% for Group B standing).

CONCLUSION

The Surgimap smartphone application is a reliable and accurate method for craniovertebral angle measurement and is useful for measuring outcomes. Also standing posture was found to be better than sitting posture while measuring the CVA.

摘要

背景

颅椎角(CVA)改变是颈部、肩部和颞下颌关节疾病的一个致病因素。因此,作为治疗干预的一项结果指标,使用Surgimap智能手机应用程序测量颅椎角是一种经济高效、易于获取且可靠的工具。本研究的目的是评估Surgimap智能手机应用程序与Surgimap系统软件测量不同年龄组和体位下颅椎角的临床测量特性。

方法

90名颈部疼痛患者被随机分为18至30岁组(A组;n = 45)和45至60岁组(B组;n = 45)。使用Surgimap智能手机应用程序和Surgimap系统软件,在矢状面客观测量颅椎角。组内相关系数用于确定有效性和可靠性。绘制受试者工作特征(ROC)曲线并计算曲线下面积(AUC),以区分有无头部前倾姿势的参与者。

结果

本研究结果表明,智能手机Surgimap应用程序与Surgimap系统软件的相关性为0.95,不同体位和年龄的p值均为0.01。无论采用何种方法或年龄,坐位时的CVA测量值均显著低于站立位。两种体位均显示出较高的评分者内可靠性,组内相关系数(ICC)在0.972至0.991之间。最小可检测变化(MDC)值在1.3至1.733之间,表明测量精度较高。智能手机应用程序显示出出色的诊断敏感性(A组站立位为100.00%)和特异性(B组站立位为93.55%)。

结论

Surgimap智能手机应用程序是一种可靠且准确的颅椎角测量方法,对测量结果很有用。此外,在测量CVA时,站立姿势优于坐姿。