Suppr超能文献

注射柜内玻璃体内注射的安全性概况:7238次注射后未出现眼内炎病例。

Safety Profile of Intravitreal Injections in the Injection Cabinet: No Cases of Endophthalmitis Seen After 7238 Injections.

作者信息

Ozgur Gokhan, Gokmen Onur

机构信息

Department of Ophthalmology, Samsun University, Samsun, Türkiye.

Department of Ophthalmology, Yuzuncu Yıl University, Van, Türkiye.

出版信息

Beyoglu Eye J. 2023 Dec 1;8(4):280-286. doi: 10.14744/bej.2023.98216. eCollection 2023.

Abstract

OBJECTIVES

The present study evaluates the rate of endophthalmitis in intravitreal injections (IVI) performed in a modular injection cabin that could be easily sited in a closet in an office environment, and the performance tests of the cabin in terms of heating, ventilation, and air conditioning (HVAC).

METHODS

The injections were given over approximately 18 months in the cabin and the demographics of the patients were screened retrospectively, and the cabin was subjected to HVAC tests.

RESULTS

A total of 7,238 injections were performed in the defined period, and no cases of endophthalmitis were encountered (0%). The results of the airflow and flow rate, particle count, pressure difference, decontamination time, light, moisture, and heat tests were all found to be above the standard defined by the International Organization for Standardization (ISO).

CONCLUSION

An injection cabin is a practical modular construction that can be easily sited in any space without the need for special climatization, and provides a sterile and safe environment for IVI.

摘要

目的

本研究评估了在模块化注射舱内进行玻璃体内注射(IVI)时眼内炎的发生率,该注射舱可轻松安置在办公室环境的壁橱中,并对该舱在加热、通风和空调(HVAC)方面的性能进行测试。

方法

在该舱内进行了约18个月的注射,并对患者的人口统计学数据进行回顾性筛查,同时对该舱进行HVAC测试。

结果

在规定期间共进行了7238次注射,未出现眼内炎病例(0%)。气流和流速、颗粒计数、压差、净化时间、光照、湿度和热测试结果均高于国际标准化组织(ISO)规定的标准。

结论

注射舱是一种实用的模块化结构,可轻松安置在任何空间,无需特殊气候调节,并为玻璃体内注射提供无菌和安全的环境。