van den Berg P, Schmidt S, Gesche J, Saling E
Br J Obstet Gynaecol. 1987 Jan;94(1):72-5. doi: 10.1111/j.1471-0528.1987.tb02256.x.
The efficacy of electronic fetal monitoring combined with fetal blood analysis during labour in identifying fetal distress was investigated in a retrospective study. Operative delivery for fetal distress diagnosed during labour was performed in 9% of 2659 deliveries. All had continuous fetal heart rate monitoring and 22% had a fetal scalp blood analysis. Operative delivery had been performed in 53% of the infants who were acidotic at birth (umbilical artery pH less than 7.20) and in 46% of those with a low modified Apgar score (less than 7). These results show that the use of continuous fetal heart rate monitoring and fetal scalp blood sampling detects fetal distress without resulting in a high rate of operative delivery.