BACKGROUND/PURPOSE: Current 3D-printing technology has been widely used for creating dental resin restorations. This study aimed to evaluate the effect of light intensity, time, and energy post-curing on the surface color of 3D-printed resin crowns. However, the influences of post-curing parameters on the restoration after printing still need to be explored. Therefore, this project investigates the effect of post-cure conditions on resin color.
Specimens from single-crown (SC) and pontic (PO) specimens underwent post-curing at various light intensities (105, 210, 420, 630, and 860 mW/cm2) for 5, 10, and 15 min. Specimens were observed at three predetermined points and measured using a commercial spectrophotometer that utilizes the CIE Lab∗ color space. Subsequently, samples were analyzed for color differences (ΔE).
ΔE color differences in evaluated samples were influenced by the light intensity, time, and energy post-curing. SC samples showed a significant color difference ( < 0.05), with the lowest value at 5 min of 16 (860 mW/cm), while 10 and 15 min had a difference of 4 (210 mW/cm). PO samples exhibited a significant decrease in the color difference ( < 0.05) at 5 and 10 min of 16 (860 mW/cm), and at 15 min of 12 (630 mW/cm).
The results of this study indicate that exposing a resin crown to a high light intensity results in color stability and allows shorter post-curing times.
背景/目的:当前3D打印技术已广泛应用于制作牙科树脂修复体。本研究旨在评估光强度、时间和后固化能量对3D打印树脂冠表面颜色的影响。然而,打印后后固化参数对修复体的影响仍有待探索。因此,本项目研究后固化条件对树脂颜色的影响。
单冠(SC)和桥体(PO)样本在不同光强度(105、210、420、630和860 mW/cm²)下后固化5、10和15分钟。在三个预定点观察样本,并使用采用CIE Lab∗颜色空间的商用分光光度计进行测量。随后,分析样本的颜色差异(ΔE)。
评估样本中的ΔE颜色差异受光强度、时间和后固化能量的影响。SC样本显示出显著的颜色差异(<0.05),在860 mW/cm下5分钟时最低值为16,而10分钟和15分钟时在210 mW/cm下差异为4。PO样本在860 mW/cm下5分钟和10分钟时颜色差异显著降低(<0.05),在630 mW/cm下15分钟时为12。
本研究结果表明,将树脂冠暴露于高光强度下可实现颜色稳定性,并允许缩短后固化时间。