• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

ChromoTimeSystem--a new generation of coagulation analyses.

作者信息

Kolde H J

出版信息

Behring Inst Mitt. 1985 Dec(78):176-87.

PMID:3833242
Abstract

A new system of reagents and a dedicated instrument for coagulation and fibrinolysis assays, the ChromoTimeSystem is described. All assays are performed in the Chromotimer, a microprocessor controlled 4 channel photometer which is connected to micro computer. Most of the reagents use chromogenic substrates. PT, APTT, fibrinogen, reptilase time and thrombin time are all performed with 25 microliters of sample and 250 microliters of reagent. Neither predilution nor preincubation steps are necessary improving these photometric assays in respect to practicability and speed compared to coagulometric techniques. The use of photometry in contrast to the varying physical principles of classical coagulation analysis will be a step forward into standardization.

摘要

相似文献

1
ChromoTimeSystem--a new generation of coagulation analyses.
Behring Inst Mitt. 1985 Dec(78):176-87.
2
New perspectives in diagnosis of hemostasis disorders.止血障碍诊断的新视角。
Ann Biol Clin (Paris). 1988;46(3):201-10.
3
Evaluation of "Statsep," a semiautomated device to prepare plasma samples for coagulation analysis.
Semin Thromb Hemost. 1983 Oct;9(4):334-40.
4
Application of several chromogenic substrate assays to automated instrumentation for coagulation analysis.
Semin Thromb Hemost. 1983 Oct;9(4):301-8.
5
A simultaneous evaluation of three multiparametric coagulation instruments: BFA, HEMOLAB and STA.
Nouv Rev Fr Hematol (1978). 1994 Dec;36(6):409-18.
6
Standardization of coagulation tests.凝血试验的标准化。
Southeast Asian J Trop Med Public Health. 1999;30 Suppl 3:79-85.
7
Evaluation of the Q analyzer, a new cap-piercing fully automated coagulometer with clotting, chromogenic, and immunoturbidometric capability.新型具有穿刺帽的全自动凝血分析仪Q分析仪的评估,该分析仪具备凝血、发色底物法及免疫比浊检测功能。
Blood Coagul Fibrinolysis. 2013 Jan;24(1):28-34. doi: 10.1097/MBC.0b013e3283597621.
8
Problems with assays based on fibrin clot formation principle: analysis of multilaboratory data.基于纤维蛋白凝块形成原理的检测方法存在的问题:多实验室数据分析
Osaka City Med J. 1998 Jun;44(1):55-71.
9
[Prothrombin time, activated partial thromboplastin time, plasma fibrinogen determination. Comparison of two automated coagulation systems: Koagulab 40-A and ACL-100].
Ann Biol Clin (Paris). 1991;49(10):507-13.
10
Multicenter evaluation of a chromogenic substrate method for photometric determination of prothrombin time.用于光度法测定凝血酶原时间的显色底物法的多中心评估。
Thromb Haemost. 1987 Oct 28;58(3):856-65.