Tamura Yuma, Ochiai Kaori, Takahashi Momo, Takahashi Harunori, Tomoe Takashi, Sugiyama Takushi, Otani Naoyuki, Sugimura Hiroyuki, Toyoda Shigeru, Yasu Takanori
Department of Rehabilitation, Dokkyo Medical University Nikko Medical Center, Nikko, JPN.
Department of Cardiology, Dokkyo Medical University Nikko Medical Center, Nikko, JPN.
Cureus. 2024 Jan 9;16(1):e51919. doi: 10.7759/cureus.51919. eCollection 2024 Jan.
Background Belt electrode skeletal muscle stimulation (B-SES) is an alternative exercise therapy for those with difficulty performing voluntary exercise. However, it is unknown whether oxygen uptake (VO) in B-SES is comparable to cardiopulmonary exercise test (CPX) as assessed by voluntary exercise. This study aimed to evaluate oxygen uptake (VO) and lactate (LA) production in incremental B-SES compared to ergometer CPX and to determine the relationship with ergometer CPX. Methods This study included 10 healthy young Japanese participants. Using a crossover design, all participants underwent incremental B-SES CPX and ergometer CPX using a 20 W ramp. Serum lactic acid concentration (LA) was measured serially before, during, and after B-SES. The tolerability of B-SES was adjusted with the change in LA level (⊿LA). Results Peak VO during B-SES (14.1±3.3 mL/kg/min) was significantly lower than ergometer peak VO (30.2±6.2 mL/kg/min, P<0.001). B-SES peak VO was similar to the anaerobic threshold (AT) VO on ergometer CPX (15.1±2.6 mL/kg/min). LA (Rest: 1.4±0.3, Peak: 2.8±0.8 mmol) and plasma noradrenalin (Rest: 0.2±0.1, Peak: 0.4±0.1 ng/mL) levels increased after B-SES. No significant correlation was observed between B-SES peak VO and ergometer CPX. However, after adjusting for B-SES, tolerability, it (peak VO of B-SES /⊿LA) correlated with peak VO (r=0.688, p=0.028) on the ergometer. Conclusion Peak VO of the passively progressive B-SES almost reached the AT value of the ergometer CPX without adverse events. Peak VO of B-SES adjusted with ⊿LA may be used to predict peak VO in ergometer CPX.
腰带电极骨骼肌刺激(B-SES)是一种为那些进行自主运动有困难的人提供的替代性运动疗法。然而,B-SES中的摄氧量(VO)是否与通过自主运动评估的心肺运动试验(CPX)相当尚不清楚。本研究旨在评估递增式B-SES与测力计CPX相比的摄氧量(VO)和乳酸(LA)生成情况,并确定其与测力计CPX的关系。方法:本研究纳入了10名健康的日本年轻参与者。采用交叉设计,所有参与者使用20W斜坡进行递增式B-SES、CPX和测力计CPX。在B-SES之前、期间和之后连续测量血清乳酸浓度(LA)。根据LA水平变化(⊿LA)调整B-SES的耐受性。结果:B-SES期间的峰值VO(14.1±3.3 mL/kg/min)显著低于测力计的峰值VO(30.2±6.2 mL/kg/min,P<0.001)。B-SES的峰值VO与测力计CPX上的无氧阈值(AT)VO相似(15.1±2.6 mL/kg/min)。B-SES后LA(静息:1.4±0.3,峰值:2.8±0.8 mmol)和血浆去甲肾上腺素(静息:0.2±0.1,峰值:0.4±0.1 ng/mL)水平升高。B-SES的峰值VO与测力计CPX之间未观察到显著相关性。然而,在调整B-SES的耐受性后,其(B-SES的峰值VO/⊿LA)与测力计上的峰值VO相关(r=0.688,p=0.028)。结论:被动渐进式B-SES的峰值VO几乎达到了测力计CPX的AT值,且无不良事件。经⊿LA调整后的B-SES峰值VO可用于预测测力计CPX中的峰值VO。