The aim was to evaluate the difference in the heat generated between zirconia (Zr) and steel (SS) drills, during implant site preparation.
This systematic review followed the PRISMA methodology criteria and used the JBI Critical Assessment Guidelines for Quasi-Experimental Studies for quality assessment. The electronic search was conducted by using the PubMed/MEDLINE, Embase, and Cochrane Library databases to January 2023. The formulated population, intervention, comparison, outcome (PICO) question was "Do zirconia drills generate less heat than steel drills during implant site preparation?". The meta-analysis was based on an inverse variance (IV) method.
This review included 10 studies in vitro that used zirconia drills compared to steel drills with or without coatings. The meta-analysis indicated a significant difference between Zr drills and SS drills, with a lower bone temperature variation with Zr drills.
Despite the limitations of this review, it was concluded that Zr drills had significantly less temperature variation than SS drills.
评估在种植体植入部位制备过程中,氧化锆(Zr)钻头和不锈钢(SS)钻头产生热量的差异。
本系统评价遵循PRISMA方法学标准,并使用JBI准实验研究关键评估指南进行质量评估。通过检索PubMed/MEDLINE、Embase和Cochrane图书馆数据库至2023年1月进行电子检索。制定的人群、干预措施、对照、结局(PICO)问题是“在种植体植入部位制备过程中,氧化锆钻头产生的热量是否比不锈钢钻头少?”。荟萃分析基于逆方差(IV)方法。
本评价纳入了10项体外研究,这些研究比较了有涂层或无涂层的氧化锆钻头与不锈钢钻头。荟萃分析表明,Zr钻头和SS钻头之间存在显著差异,Zr钻头的骨温变化较小。
尽管本评价存在局限性,但得出的结论是,Zr钻头的温度变化明显小于SS钻头。