Suzuki Nami, Takeuchi Miki, Miyazaki Naoko, Tanaka Katsumasa, Utsunomiya Sosuke, Arai Yoshiyuki, Yoshimura Toru, Sugino Kiminori, Ito Koichi, Noh Jaeduk Yoshimura
Department of Internal Medicine, Ito Hospital, Tokyo 150-8308, Japan.
Diagnostic Division, Abbott Japan LLC, Matsudo, Chiba 270-2214, Japan.
J Endocr Soc. 2024 Feb 14;8(4):bvae030. doi: 10.1210/jendso/bvae030. eCollection 2024 Feb 19.
The remote performance of thyroid function blood tests is complicated because it requires blood collection.
To compare TSH and free thyroxine (FT4) levels between capillary and venous blood and assess the adequacy of measuring each value in capillary blood.
This prospective intervention study was conducted at Ito Hospital and was based on the clinical research method. The participants were 5 healthy female volunteers and 50 patients (41 females and 9 males) between the ages of 23 and 81 years. To measure TSH and FT4 levels in capillary and venous blood, a digital immunoassay (d-IA) method capable of measuring trace samples was used. Chemiluminescence measurements were used as controls. Values obtained for each assay system were compared using Spearman's correlation analysis. Capillary blood was collected using an autologous device (TAP II; not approved in Japan).
Capillary plasma volume obtained using TAP II was 125 µL or more in 26 cases, 25 µL to 124 µL in 24 cases, and less than 25 µL in 5 cases. Strong correlations were noted in the TSH and FT4 levels between capillary and venous blood, with correlation coefficients of rs = 0.99 and rs = 0.97, respectively.
Capillary TSH and FT4 levels strongly correlate with venous blood values. Trace samples can be used in high-precision d-IA methods. These results may promote telemedicine in assessing thyroid function.
甲状腺功能血液检测的远程操作很复杂,因为它需要进行血液采集。
比较毛细血管血和静脉血中促甲状腺激素(TSH)和游离甲状腺素(FT4)水平,并评估测量毛细血管血中各值的充分性。
这项前瞻性干预研究在伊藤医院进行,基于临床研究方法。参与者为5名健康女性志愿者和50名年龄在23至81岁之间的患者(41名女性和9名男性)。为了测量毛细血管血和静脉血中的TSH和FT4水平,使用了一种能够测量微量样本的数字免疫分析(d-IA)方法。化学发光测量用作对照。使用Spearman相关性分析比较每个检测系统获得的值。使用自体装置(TAP II;未在日本获批)采集毛细血管血。
使用TAP II获得的毛细血管血浆量,26例为125微升或更多,24例为25至124微升,5例少于25微升。毛细血管血和静脉血中的TSH和FT4水平存在强相关性,相关系数分别为rs = 0.99和rs = 0.97。
毛细血管TSH和FT4水平与静脉血值密切相关。微量样本可用于高精度d-IA方法。这些结果可能会促进甲状腺功能评估中的远程医疗。