Suppr超能文献

在丹麦健身中心进行兴奋剂检查期间,对配对的干血斑和尿液样本中的兴奋剂物质进行检测。

Detection of doping substances in paired dried blood spots and urine samples collected during doping controls in Danish fitness centers.

作者信息

Levernæs Maren Christin Stillesby, Solheim Sara A, Broderstad Lillian, Zandy Essa, Mørkeberg Jakob, Dehnes Yvette

机构信息

Norwegian Doping Control Laboratory, Oslo University Hospital, Oslo, Norway.

Science and Research, Anti Doping Denmark, Brøndby, Denmark.

出版信息

Drug Test Anal. 2024 Dec;16(12):1510-1527. doi: 10.1002/dta.3660. Epub 2024 Mar 3.

Abstract

The use of dried blood spot (DBS) in anti-doping can be advantageous in terms of collection, transportation, and storage compared with the traditional anti-doping testing matrices urine and venous blood. There could, nonetheless, be disadvantages such as shorter detection windows for some substances compared with urine, but real-life comparison of the detectability of prohibited substances in DBS and urine is lacking. Herein, we present a liquid chromatography-high resolution mass spectrometry (LC-HRMS)-based screening method for simultaneous detection of 19 target analytes from the doping substance categories S1-S5 in a single spot. Ninety-eight urine and upper-arm DBS (Tasso-M20) sample pairs were collected from fitness centers customers notified for doping control by Anti Doping Denmark, and three sample pairs were collected from active steroid users undergoing clinical evaluation and treatment at a Danish hospital. The analytical findings were cross compared to evaluate the applicability of the developed DBS testing menu in terms of feasibility and analytical performance. To our knowledge, this is the first study to compare the detectability of prohibited substances in DBS and urine samples collected in a doping control setting. Twenty-seven of the urine samples and 23 DBS samples were positive, and we observed a very high concordance (95%) in the overall analytical results (i.e., positive or negative samples for both urine and DBS). Collectively, these results are very promising, and DBS seems suitable as a stand-alone matrix in doping control in fitness centers likely because of the high analyte concentration levels in these samples.

摘要

与传统的反兴奋剂检测样本(尿液和静脉血)相比,在反兴奋剂检测中使用干血斑(DBS)在采集、运输和储存方面具有优势。然而,也可能存在一些缺点,例如与尿液相比,某些物质的检测窗口期较短,但缺乏干血斑和尿液中违禁物质可检测性的实际对比。在此,我们提出一种基于液相色谱 - 高分辨率质谱(LC - HRMS)的筛查方法,用于在单个斑点中同时检测来自兴奋剂物质类别S1 - S5的19种目标分析物。从丹麦反兴奋剂机构通知进行兴奋剂检测的健身中心客户中收集了98对尿液和上臂干血斑(Tasso - M20)样本,并从丹麦一家医院正在接受临床评估和治疗的活性类固醇使用者中收集了3对样本。对分析结果进行交叉比较,以评估所开发的干血斑检测菜单在可行性和分析性能方面的适用性。据我们所知,这是第一项比较在兴奋剂检测环境中收集的干血斑和尿液样本中违禁物质可检测性的研究。27份尿液样本和23份干血斑样本呈阳性,我们观察到总体分析结果(即尿液和干血斑样本均为阳性或阴性)具有非常高的一致性(95%)。总体而言,这些结果非常有前景,干血斑似乎适合作为健身中心兴奋剂检测中的独立样本基质,这可能是因为这些样本中分析物浓度水平较高。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dde1/11635062/4b1e9c338f1d/DTA-16-1510-g002.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验