Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China.
Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003, China.
Talanta. 2024 Jun 1;273:125876. doi: 10.1016/j.talanta.2024.125876. Epub 2024 Mar 5.
The high level of alpha-fetoprotein (AFP) expression is closely related to hepatocellular carcinoma (HCC). Herein, a dual signal ratiometric electrochemical immunosensor based on chitosan-ferrocenecarboxaldehyde-spindle gold (Chit-Fc-SAu) and Co/Fe metal-organic framework-toluidine blue/polydopamine (Co/Fe MOF-TB/PDA) was proposed for quantitative analysis of AFP. Specifically, Chit-Fc-SAu worked as a substrate to trap more primary antibodies (Ab) generating the first electrochemical signal from Fc. Thanks to the large specific surface area, the synergistic and electronic effects of Co/Fe MOF nanosheets, and the rich functional groups of PDA, Co/Fe MOF-TB/PDA could load more secondary antibodies (Ab) and signal molecules (TB) providing another amplified electrochemical signal. In the presence of AFP, Ab-AFP-Ab formed a sandwich structure, and as the AFP concentration increased, the peak current ratio of TB to Fc (I/I) also increased. The dual signal ratiometric strategy can avoid environmental signal interference and achieve signal self-calibration, thereby improving the accuracy and reproducibility of detection. After a series of exploration, this self-calibrated ratiometric immunosensor exhibited a wide linear range (0.001-200 ng mL), a low detection limit (0.34 pg mL), and good repeatability. When applied to the assay of clinical serum samples, the detection results of ratiometric sensor were consistent with that of commercial electrochemiluminescence (ECL) immunoassay, significantly superior to that of non-ratiometric sensor. The self-calibrated strategy based on ratiometric sensor helps to improve the accuracy of AFP in clinical diagnosis.
甲胎蛋白(AFP)的高表达水平与肝细胞癌(HCC)密切相关。在此,提出了一种基于壳聚糖-二茂铁-梭形金(Chit-Fc-SAu)和 Co/Fe 金属有机骨架-甲苯胺蓝/聚多巴胺(Co/Fe MOF-TB/PDA)的双信号比率电化学免疫传感器,用于 AFP 的定量分析。具体来说,Chit-Fc-SAu 用作捕获更多捕获抗体(Ab)的基质,从而从 Fc 产生第一个电化学信号。由于 Co/Fe MOF 纳米片具有较大的比表面积、协同和电子效应以及 PDA 丰富的官能团,Co/Fe MOF-TB/PDA 可以负载更多的二抗(Ab)和信号分子(TB),提供另一个放大的电化学信号。在 AFP 存在的情况下,Ab-AFP-Ab 形成三明治结构,随着 AFP 浓度的增加,TB 与 Fc 的峰电流比(I/I)也增加。双信号比率策略可以避免环境信号干扰并实现信号自校准,从而提高检测的准确性和重现性。经过一系列探索,这种自校准比率免疫传感器表现出宽线性范围(0.001-200 ng mL)、低检测限(0.34 pg mL)和良好的重复性。当应用于临床血清样品的测定时,比率传感器的检测结果与商业电化学发光(ECL)免疫分析一致,明显优于非比率传感器。基于比率传感器的自校准策略有助于提高 AFP 在临床诊断中的准确性。