Knee kinematics during a drop vertical jump, measured by the Kinect V2 (Microsoft, Redmond, WA, USA), have been shown to be associated with an increased risk of non-contact anterior cruciate ligament injury. The accuracy and reliability of the Microsoft Kinect V2 has yet to be assessed specifically for tracking the coronal and sagittal knee angles of the drop vertical jump. Eleven participants performed three drop vertical jumps that were recorded using both the Kinect V2 and a gold standard motion analysis system (Vicon, Los Angeles, CA, USA). The initial coronal, peak coronal, and peak sagittal angles of the left and right knees were measured by both systems simultaneously. Analysis of the data obtained by the Kinect V2 was performed by our software. The differences in the mean knee angles measured by the Kinect V2 and the Vicon system were non-significant for all parameters except for the peak sagittal angle of the right leg with a difference of 7.74 degrees and a -value of 0.008. There was excellent agreement between the Kinect V2 and the Vicon system, with intraclass correlation coefficients consistently over 0.75 for all knee angles measured. Visual analysis revealed a moderate frame-to-frame variability for coronal angles measured by the Kinect V2. The Kinect V2 can be used to capture knee coronal and sagittal angles with sufficient accuracy during a drop vertical jump, suggesting that a Kinect-based portable motion analysis system is suitable to screen individuals for the risk of non-contact anterior cruciate ligament injury.

摘要

在垂直跳下落过程中,使用 Kinect V2(微软,雷蒙德,华盛顿州,美国)测量的膝关节运动学与非接触性前交叉韧带损伤的风险增加有关。 但是,尚未专门评估 Microsoft Kinect V2 用于跟踪垂直跳下落过程中冠状和矢状位膝关节角度的准确性和可靠性。 11 名参与者进行了三次垂直跳下落,这三次跳跃都使用 Kinect V2 和黄金标准运动分析系统(Vicon,洛杉矶,加利福尼亚州,美国)进行了记录。 同时通过两个系统测量左膝和右膝的初始冠状面,峰值冠状面和峰值矢状面角度。 我们的软件对 Kinect V2 获得的数据进行了分析。 除了右腿的峰值矢状角的差异为 7.74 度,β值为 0.008 外,Kinect V2 和 Vicon 系统测量的平均膝关节角度之间的差异无统计学意义。 Kinect V2 和 Vicon 系统之间具有极好的一致性,所有测量的膝关节角度的组内相关系数均始终超过 0.75。 视觉分析显示 Kinect V2 测量的冠状面角度的帧间变异性中等。 Kinect V2 可用于在垂直跳下落过程中以足够的精度捕获膝关节冠状和矢状角度,这表明基于 Kinect 的便携式运动分析系统适合筛选非接触性前交叉韧带损伤风险的个体。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/42d5/10974175/22d594fbc602/sensors-24-01970-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验