Suppr超能文献

应用血栓纤维蛋白溶解波形分析和整体纤维蛋白溶解能力检测与旋转血栓弹力描记术检测结果的比较。

Comparison of results obtained using clot-fibrinolysis waveform analysis and global fibrinolysis capacity assay with rotational thromboelastography.

机构信息

Division of Acute and Critical Care Medicine, Department of Anesthesiology and Critical Care Medicine, Faculty of Medicine, Hokkaido University, Sapporo, Japan.

Sysmex Corporation, Kobe, Japan.

出版信息

Sci Rep. 2024 Mar 31;14(1):7602. doi: 10.1038/s41598-024-58436-6.

Abstract

Global fibrinolysis assays detect the fibrinolysis time of clot dissolution using tissue-type plasminogen activator (tPA). Two such assays, clot-fibrinolysis waveform analysis (CFWA) and global fibrinolysis capacity (GFC) assay, were recently developed. These were compared with rotational thromboelastography (ROTEM). Healthy donor blood samples were divided into four groups based on tPA-spiked concentrations: 0, 100, 500, and 1000 ng/mL. CFWA and GFC fibrinolysis times, including 4.1 µg/mL and 100 ng/mL tPA in the assays, were determined, denoted as CFWA-Lys and GFC-Lys, respectively. Statistical differences were recognized between tPA concentrations of 0 and 500/1000 ng/mL for CFWA-Lys, and 0 and 100/500/1000 ng/mL for GFC-Lys. The correlation coefficients with lysis onset time (LOT) of extrinsic pathway evaluation and intrinsic pathway evaluation in ROTEM were statistically significant at 0.610 and 0.590 for CFWA-Lys, and 0.939 and 0.928 for GFC-Lys, respectively (p-values < 0.0001 for all correlations). Both assays showed significant correlations with ROTEM; however, the GFC assay proved to have better agreement with ROTEM compared with the CFWA assay. These assays have the potential to reflect a hyperfibrinolysis status with high tPA concentrations.

摘要

全球纤溶测定法使用组织型纤溶酶原激活物(tPA)来检测血栓溶解的纤溶时间。最近开发了两种这样的测定法,即凝块纤溶波分析(CFWA)和整体纤溶能力(GFC)测定法。将这些方法与旋转血栓弹性测定法(ROTEM)进行了比较。根据 tPA 加标浓度将健康供体血液样本分为四组:0、100、500 和 1000ng/mL。测定了 CFWA 和 GFC 纤溶时间,其中 CFWA 和 GFC 测定法中分别包含 4.1μg/mL 和 100ng/mL 的 tPA,分别表示为 CFWA-Lys 和 GFC-Lys。CFWA-Lys 在 tPA 浓度为 0 和 500/1000ng/mL 之间以及 GFC-Lys 在 tPA 浓度为 0 和 100/500/1000ng/mL 之间存在统计学差异。CFWA-Lys 与 ROTEM 外源性途径评估和内在途径评估的裂解起始时间(LOT)的相关系数分别为 0.610 和 0.590,GFC-Lys 分别为 0.939 和 0.928(所有相关性的 p 值均<0.0001)。这两种测定法均与 ROTEM 有显著相关性,但与 CFWA 测定法相比,GFC 测定法与 ROTEM 的一致性更好。这些测定法具有反映高浓度 tPA 下的高纤溶状态的潜力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5a98/10982290/0efecb7c37a1/41598_2024_58436_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验