Suppr超能文献

关节置换术中的脉冲冲洗:一项系统评价和荟萃分析。

Pulsed lavage in joint arthroplasty: A systematic review and meta-analysis.

作者信息

Daher Mohammad, Haykal Gaby, Aoun Marven, Moussallem Marc, Ghoul Ali, Tarchichi Jean, Sebaaly Amer

机构信息

Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon.

出版信息

World J Orthop. 2024 Mar 18;15(3):293-301. doi: 10.5312/wjo.v15.i3.293.

Abstract

BACKGROUND

Knee and hip osteoarthritis affects millions of people around the world and is expected to rise even more in frequency as the population ages. Joint arthroplasty is the surgical management of choice in these articulations. Heterotopic ossification and radiolucent lines formation are two frequent problems faced in hip and knee replacements respectively. Some studies show that the usage of pulsed lavage may prevent their formation.

AIM

To compare pulsed lavage to standard lavage in joint arthroplasty.

METHODS

PubMed, Cochrane, and Google Scholar (page 1-20) were searched till December 2023. Only comparative studies were included. The clinical outcomes evaluated were the heterotopic ossification formation in hip replacements, radiolucent lines formation, and functional knee scores in knee replacements.

RESULTS

Four studies met the inclusion criteria and were included in this meta-analysis. Pulsed lavage was shown to reduce the formation of radiolucent lines ( = 0.001). However, no difference was seen in the remaining outcomes.

CONCLUSION

Pulsed lavage reduced the formation of radiolucent lines in knee replacements. No difference was seen in the remaining outcomes. Furthermore, the clinical significance of these radiolucent lines is poorly understood. Better conducted randomized controlled studies and cost-effectivity studies are needed to reinforce these findings.

摘要

背景

膝关节和髋关节骨关节炎影响着全球数百万人,并且随着人口老龄化,其发病率预计还会进一步上升。关节置换术是这些关节的首选手术治疗方法。异位骨化和透亮线形成分别是髋关节和膝关节置换术中常见的两个问题。一些研究表明,脉冲冲洗的使用可能会预防它们的形成。

目的

比较关节置换术中脉冲冲洗与标准冲洗。

方法

检索截至2023年12月的PubMed、Cochrane和谷歌学术(第1 - 20页)。仅纳入比较研究。评估的临床结果包括髋关节置换术中异位骨化的形成、透亮线的形成以及膝关节置换术中的膝关节功能评分。

结果

四项研究符合纳入标准并被纳入该荟萃分析。结果显示脉冲冲洗可减少透亮线的形成(P = 0.001)。然而,在其余结果中未发现差异。

结论

脉冲冲洗减少了膝关节置换术中透亮线的形成。在其余结果中未发现差异。此外,这些透亮线的临床意义尚不清楚。需要开展更好的随机对照研究和成本效益研究来强化这些发现。