Suppr超能文献

两分钟站立耐力测试用于帕金森病患者的轴向姿势异常。

Two-minute standing endurance test for axial postural abnormalities in patients with Parkinson's disease.

机构信息

Department of Physical Rehabilitation, National Center Hospital, National Center of Neurology and Psychiatry, Tokyo, Japan.

Department of Physical Rehabilitation, National Center Hospital, National Center of Neurology and Psychiatry, Tokyo, Japan.

出版信息

Gait Posture. 2024 Jul;112:81-87. doi: 10.1016/j.gaitpost.2024.05.001. Epub 2024 May 14.

Abstract

BACKGROUND

Photo-based measurement methods are used to assess axial postural abnormalities (PA) in Parkinson's disease (PD). However, they capture only moments in time. We developed the 2-minute standing endurance test (2 M-SET), which specifically captures temporal changes in posture, as a novel dynamic method for measuring axial PA in patients with PD.

RESEARCH QUESTION

This study aimed to verify the effectiveness and validity of the 2 M-SET for capturing temporal changes in axial PA in patients with PD.

METHODS

Twenty-eight patients with PD participated. The participants attempted to maintain an upright posture for 2 minutes during three tasks: standing, stepping in place, and walking. The rate of change in postural angle was recorded at 10-second intervals. Based on the results, the 2 M-SET was developed. Therapists evaluated the 2 M-SET using the NeuroPostureApp© to measure anterior trunk flexion (ATF) angles and lateral trunk flexion (LTF) angles at 0, 10, 30, 60, and 120 seconds. To assess reliability, the congruence between the measurements obtained by the therapists and those obtained using a three-dimensional motion-analysis system was examined. For validity, we assessed whether the ATF and LTF angles measured by the therapists could accurately capture postural changes at regular intervals over time.

RESULTS

The average postural changes over 2 minutes for the standing, stepping in place, and gait tasks were 59.2±83.5%, 37.6±30.7%, and 45.4±50.6%, respectively. The intraclass correlation coefficients showed high reliability, with values of 0.985 and 0.970 for the ATF and LTF angles, respectively.

SIGNIFICANCE

The results of our proposed 2 M-SET method, which uses temporal photo-based measurements to assess the patient's ability to maintain an upright standing position for 2 minutes, demonstrate the potential to capture temporal changes in axial PA.

DATA AVAILABILITY STATEMENT

The data supporting the findings of this study are available upon reasonable request and approval from the local ethics committee.

摘要

背景

基于照片的测量方法用于评估帕金森病(PD)患者的轴向姿势异常(PA)。然而,它们仅捕捉到瞬间。我们开发了 2 分钟站立耐力测试(2M-SET),这是一种专门用于测量 PD 患者轴向 PA 的动态方法,可以捕捉姿势的时间变化。

研究问题

本研究旨在验证 2M-SET 捕捉 PD 患者轴向 PA 时间变化的有效性和有效性。

方法

28 名 PD 患者参加了这项研究。参与者在三项任务(站立、原地踏步和行走)中尝试保持 2 分钟的直立姿势:站立、原地踏步和行走。以 10 秒为间隔记录姿势角度的变化率。基于结果,开发了 2M-SET。治疗师使用 NeuroPostureApp©评估 2M-SET,以测量前躯干屈曲(ATF)角度和侧躯干屈曲(LTF)角度,在 0、10、30、60 和 120 秒时。为了评估可靠性,检查了治疗师测量值与三维运动分析系统测量值之间的一致性。为了评估有效性,我们评估了治疗师测量的 ATF 和 LTF 角度是否可以准确地捕获随时间的定期姿势变化。

结果

站立、原地踏步和步行任务 2 分钟内的平均姿势变化分别为 59.2±83.5%、37.6±30.7%和 45.4±50.6%。ATF 和 LTF 角度的组内相关系数显示出高度的可靠性,分别为 0.985 和 0.970。

意义

我们提出的 2M-SET 方法使用时间基于照片的测量来评估患者保持直立站立 2 分钟的能力,结果表明有潜力捕捉轴向 PA 的时间变化。

数据可用性声明

支持本研究发现的数据可应要求并经当地伦理委员会批准后提供。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验