Suppr超能文献

社区居住、社会孤立的老年人居家远程自我管理功能能力评估的重测信度和一致性

Test-retest reliability and agreement of remote home-based functional capacity self-administered assessments in community-dwelling, socially isolated older adults.

作者信息

Villar Rodrigo, Beltrame Thomas, Ferreira Dos Santos Gabriela, Zago Anderson Saranz, Bocalini Danilo Sales, Pontes Júnior Francisco Luciano

机构信息

Cardiorespiratory & Physiology of Exercise Research Laboratory, Faculty of Kinesiology and Recreation Management, University of Manitoba, Winnipeg, MB, Canada.

Department of Physical Therapy, Federal University of São Carlos, São Carlos, São Paulo, Brazil.

出版信息

Digit Health. 2024 May 21;10:20552076241254904. doi: 10.1177/20552076241254904. eCollection 2024 Jan-Dec.

Abstract

OBJECTIVES

To determine the test-retest reliability and agreement of home-based functional capacity self-administered assessments in socially isolated older adults.

METHODS

Fourteen community-dwelling older adults (eight females, 67.9 ± 7.7 years) volunteered for this study. Before testing, participants were screened online for eligibility and received instructional videos explaining test set-up and execution. Participants underwent the 30-second sit-to-standing test, gait speed tests at the usual pace, and timed-up-and-go tests administered 4 weeks apart. For the 30-second sit-to-standing protocol, participants were instructed to repeatedly sit and stand from a chair (with a height of ∼ 43 cm and without armrests) for 30 s, with the number of repetitions recorded. In the gait speed test protocol, participants were instructed to walk at their usual and comfortable pace, with the time taken recorded (seconds). In the timed-up-and-go, participants stood up from a chair, walked as fast as possible for 3 m, circled a marked point, and returned to the chair to sit down, completing the test, with the score recorded (seconds). A trained researcher conducted the scoring virtually via synchronous video.

RESULTS

30-second sit-to-standing, gait speed test, and timed-up-and-go showed excellent mean coefficient of variation values (2.0-4.9), small standard error of measurement (0.08-1.27), excellent intraclass coefficient (0.97-0.99), very strong correlations (0.97-0.99) and good agreement between the two days of testing.

CONCLUSION

Self-administered functional capacity tests performed by older adults at home were reliable with good agreement. Healthcare professionals and older adults should take advantage of simple remote self-administered assessments performed at home to evaluate older adults' health status.

摘要

目的

确定居家功能能力自我评估在社会隔离的老年人中的重测信度和一致性。

方法

14名居住在社区的老年人(8名女性,年龄67.9±7.7岁)自愿参与本研究。在测试前,通过网络对参与者进行资格筛选,并向他们提供解释测试设置和执行方法的教学视频。参与者接受30秒坐立试验、正常步速的步态速度测试以及两次测试间隔4周的计时起立行走测试。对于30秒坐立试验,要求参与者从一把高度约43厘米且无扶手的椅子上反复坐立30秒,记录重复次数。在步态速度测试中,要求参与者以其正常且舒适的步速行走,记录所用时间(秒)。在计时起立行走测试中,参与者从椅子上站起来,尽可能快地走3米,绕过一个标记点,然后回到椅子上坐下,完成测试,记录得分(秒)。一名经过培训的研究人员通过同步视频进行虚拟评分。

结果

30秒坐立试验、步态速度测试和计时起立行走测试的平均变异系数值极佳(2.0 - 4.9),测量标准误差小(0.08 - 1.27),组内相关系数极佳(0.97 - 0.99),相关性非常强(0.97 - 0.99),且两天测试之间一致性良好。

结论

老年人在家中进行的自我功能能力测试具有可靠性且一致性良好。医疗保健专业人员和老年人应利用在家中进行的简单远程自我评估来评估老年人的健康状况。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8036/11110522/92d9c228d6e2/10.1177_20552076241254904-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验