Suppr超能文献

通用测角仪、数字倾角仪和智能手机应用程序测量全膝关节置换术患者活动范围的评分者内和评分者间信度及效度

The Intrarater and Interrater Reliability and Validity of Universal Goniometer, Digital Inclinometer, and Smartphone Application Measuring Range of Motion in Patients with Total Knee Arthroplasty.

作者信息

Acar Serap, Aljumaa Heba, Şevik Kevser, Karatosun Vasfi, Ünver Bayram

机构信息

Faculty of Physical Therapy and Rehabilitation, Dokuz Eylul University, Izmir, Turkey.

Physical Therapy and Rehabilitation, Health Sciences Institute, Dokuz Eylul University, Izmir, Turkey.

出版信息

Indian J Orthop. 2024 Apr 19;58(6):732-739. doi: 10.1007/s43465-024-01129-z. eCollection 2024 Jun.

Abstract

OBJECTIVES

The aim of this study was to investigate the intrarater and interrater reliability and validity of range of motion measurements obtained with a universal goniometer, digital inclinometer, and smartphone application in patients with total knee arthroplasty.

METHODS

Range of motion of the knee joint was measured by two examiners with a universal goniometer, digital inclinometer, and a smartphone application. Data were obtained from 51 knees of 27 patients at postoperative 6 months. Two measurements made by the first examiner were compared to assess interrater reliability, and measurements from both examiners were compared to assess intrarater reliability. Statistical analysis was performed using intraclass correlation coefficient (ICC) and Spearman's rho values.

RESULTS

With all three methods, active and passive knee flexion range of motion measurements showed high intrarater and interrater reliability (ICC = 0.749-0.949). Concurrent validity analysis also demonstrated statistically significant, moderate to strong correlation among the three methods ( = 0.775-0.941).

CONCLUSION

The universal goniometer, digital inclinometer, and smartphone application were all found to be reliable and valid assessment tools in clinical practice for patients with total knee arthroplasty.

摘要

目的

本研究旨在调查使用通用角度计、数字倾角仪和智能手机应用程序对全膝关节置换术患者进行活动度测量时的测量者内和测量者间信度及效度。

方法

由两名检查者使用通用角度计、数字倾角仪和智能手机应用程序测量膝关节活动度。数据来自27例患者术后6个月的51个膝关节。比较第一位检查者进行的两次测量以评估测量者间信度,并比较两位检查者的测量结果以评估测量者内信度。使用组内相关系数(ICC)和斯皮尔曼等级相关系数值进行统计分析。

结果

使用所有三种方法时,主动和被动膝关节屈曲活动度测量均显示出较高的测量者内和测量者间信度(ICC = 0.749 - 0.949)。同时效度分析也表明三种方法之间存在统计学上显著的中度至强相关性(= 0.775 - 0.941)。

结论

在临床实践中,通用角度计、数字倾角仪和智能手机应用程序均被发现是全膝关节置换术患者可靠且有效的评估工具。

相似文献

本文引用的文献

3
The stiff total knee arthroplasty: causes, treatment modalities and results.僵硬型全膝关节置换术:病因、治疗方式及结果
EFORT Open Rev. 2019 Oct 7;4(10):602-610. doi: 10.1302/2058-5241.4.180105. eCollection 2019 Oct.
5
Flexion Instability After Total Knee Arthroplasty.膝关节置换术后的屈曲不稳定
J Am Acad Orthop Surg. 2019 Sep 1;27(17):642-651. doi: 10.5435/JAAOS-D-18-00347.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验