Suppr超能文献

扩展的执行功能日常评估:工作记忆和抑制控制任务的个体内可靠性。

Extended ambulatory assessment of executive function: within-person reliability of working memory and inhibitory control tasks.

机构信息

Melbourne School of Psychological Sciences, The University of Melbourne, Parkville, VIC, Australia.

Specialty of Addiction Medicine, Sydney Medical School, Faculty of Medicine and Health, University of Sydney, Sydney, Australia.

出版信息

J Clin Exp Neuropsychol. 2024 Jul;46(5):436-448. doi: 10.1080/13803395.2024.2364396. Epub 2024 Jun 13.

Abstract

INTRODUCTION

Ambulatory assessment of executive function - particularly in the form working memory (WM) - is increasingly common. Few studies to date, however, have also incorporated ambulatory measures of inhibitory control. Critically, the extended within-person reliability of ambulatory tasks tapping each of these constructs has been largely overlooked.

METHOD

Participants ( = 283,  = 23.74 years,  = 9.04) received notifications every 3 days (for 4 weeks) to undertake ambulatory assessment versions of the -Back and Stop-Signal Tasks (SST) via the smartphone application CheckCog. Within-person reliability of these measures was explored.

RESULTS

Compliance ranged from 66% (for eight sessions) to 89% (for four sessions). Our results reveal significant changes in performance within the first two sessions for both the -Back and SST, with performance remaining largely consistent across the remaining (two to eight) sessions. In terms of test-retest reliability, the ICC (C, 1) values ranged from .29 to .68 on the -Back (with overall accuracy being .51) and .31-.73 on the SST (with stop-signal reaction time being .53).

CONCLUSION

The results of the current study contribute to the literature by demonstrating the reliability of brief measures of executive function - in the form of inhibitory control and WM - delivered using smartphones in participants' natural environments. Based on our findings, the CheckCog app reliability tracks baseline systematic changes in WM and response inhibition across multiple time points and for an extended period in healthy individuals.

摘要

简介

目前越来越多的研究采用动态评估的方式来评估执行功能,尤其是工作记忆(WM)。然而,迄今为止,很少有研究同时纳入了对抑制控制的动态评估。重要的是,这些动态评估任务对这两种结构的个体内可靠性的扩展尚未得到充分的关注。

方法

参与者( = 283,平均年龄为 23.74 岁,女性占 9.04%)每三天(四周内)通过智能手机应用程序 CheckCog 接收通知,以进行执行功能的动态评估,包括 n-back 任务和停止信号任务(SST)。我们探讨了这些测量方法的个体内可靠性。

结果

合规性范围从 66%(8 次测试)到 89%(4 次测试)。我们的研究结果表明,在最初的两到四次测试中,n-back 和 SST 的表现都有显著变化,而在剩下的(两到八次)测试中,表现基本保持一致。就测试-再测试可靠性而言,n-back 的 ICC(C, 1)值范围为.29 到.68(整体准确性为.51),而 SST 的 ICC(C, 1)值范围为.31 到.73(停止信号反应时间为.53)。

结论

本研究的结果通过展示使用智能手机在参与者自然环境中进行的简短执行功能测量(以抑制控制和 WM 的形式)的可靠性,为文献做出了贡献。基于我们的发现,CheckCog 应用程序的可靠性可以在健康个体中,在多个时间点和较长时间段内跟踪 WM 和反应抑制的基线系统性变化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验