Ichikawa Hajime, Kato Toyohiro, Kondo Hiroki, Shimada Hideki, Shibutani Takayuki, Onoguchi Masahisa
Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, JPN.
Department of Quantum Medical Technology, Kanazawa University, Kanazawa, JPN.
Cureus. 2024 May 20;16(5):e60656. doi: 10.7759/cureus.60656. eCollection 2024 May.
Motion artifacts caused by heart motion during myocardial perfusion single-photon emission computed tomography (SPECT) can compromise image quality and diagnostic accuracy. This study aimed to evaluate the efficacy of the novel respiratory motion reduction block (RRB) device in reducing motion artifacts by compressing the hypochondrium and improving SPECT image quality.
In total, 91 patients who underwent myocardial perfusion SPECT with Tc-sestamibi were retrospectively analyzed. Patients (n = 28) who underwent SPECT without the RRB were included in the control group, and those (n = 63) who underwent SPECT with the RRB were in the RRB group. The distance of heart motion during dynamic acquisition was measured, and projection data were assessed for patient motion and motion artifacts. Patient motion was classified into various levels, and motion artifacts on SPECT images were visually examined.
The distances of heart motion without and with the RRB were 15.4 ± 5.3 and 7.5 ± 2.3, respectively. Compared with the control group, the RRB group had a lower frequency of heart motion based on the projection data, particularly in terms of creep and shift motion. The RRB group had a significantly lower incidence of motion artifacts on SPECT images than the control group.
The RRB substantially reduced specific types of motion, such as shift and creep, and had a low influence on bounce motion. However, it could effectively suppress respiratory-induced heart motion and reduce motion artifacts on myocardial perfusion SPECT, thereby emphasizing its potential for improving image quality.
在心肌灌注单光子发射计算机断层扫描(SPECT)过程中,心脏运动引起的运动伪影会影响图像质量和诊断准确性。本研究旨在评估新型呼吸运动减少阻滞(RRB)装置通过压迫季肋部减少运动伪影并改善SPECT图像质量的效果。
对总共91例行锝- sestamibi心肌灌注SPECT检查的患者进行回顾性分析。未使用RRB进行SPECT检查的患者(n = 28)纳入对照组,使用RRB进行SPECT检查的患者(n = 63)纳入RRB组。测量动态采集过程中心脏运动的距离,并评估投影数据中的患者运动和运动伪影。将患者运动分为不同级别,并对SPECT图像上的运动伪影进行视觉检查。
未使用RRB和使用RRB时心脏运动的距离分别为15.4±5.3和7.5±2.3。与对照组相比,基于投影数据,RRB组心脏运动的频率较低,尤其是在蠕动和移位运动方面。RRB组SPECT图像上运动伪影的发生率明显低于对照组。
RRB可显著减少特定类型的运动,如移位和蠕动,对跳动运动的影响较小。然而,它可以有效抑制呼吸引起的心脏运动,并减少心肌灌注SPECT上的运动伪影,从而突出其改善图像质量的潜力。