Suppr超能文献

静脉数字减影电影心血管造影术与传统对比心室造影术在静息和运动时测定左心室容积的比较。

Comparison of intravenous digital subtraction cineangiocardiography with conventional contrast ventriculography for the determination of the left ventricular volume at rest and during exercise.

作者信息

Birchler B, Hess O M, Murakami T, Niederer P, Anliker M, Krayenbuehl H P

出版信息

Eur Heart J. 1985 Jun;6(6):497-509. doi: 10.1093/oxfordjournals.eurheartj.a061895.

Abstract

Left ventricular volumes were determined by means of digital subtraction cineangiocardiography (DSA) which was performed in the right anterior oblique projection after contrast agent injection into the superior vena cava. Monoplane end-diastolic (EDV), end-systolic volumes (ESV), and ejection fraction (EF) were calculated using the 'area-length' method and were compared with the same parameters obtained by conventional left ventricular cineangiocardiography. A first group of 20 patients was studied at rest and a second group of 10 patients during bicycle exercise at a work load of 64 watts during 2 min, by DSA and conventional cineangiocardiography. Three different subtraction modes were evaluated: (1) mask mode subtraction (MMS), (2) time interval difference (TID) method and (3) a combination of MMS and TID called MMS + TID method. With the MMS method good correlations were obtained for EDV, ESV and EF at rest (r greater than 0.91) and during exercise (r greater than 0.91). The TID method showed only moderate correlations for patients at rest (r greater than 0.86) and during exercise (r greater than 0.79). Similar results as with MMS were achieved by the combined method (MMS + TID) at rest (r greater than 0.91) and during exercise (r greater than 0.91). Interobserver variability indicated a high reproducibility for all methods except for TID during exercise. It is concluded that DSA is an accurate technique for left ventricular volume determination not only at rest but also during exercise. The best results are obtained with MMS or MMS + TID methods, while left ventricular contour detection is easier and more convenient with MMS + TID.

摘要

左心室容积通过数字减法电影血管造影术(DSA)测定,该检查在向上腔静脉注射造影剂后于右前斜位进行。使用“面积-长度”法计算单平面舒张末期容积(EDV)、收缩末期容积(ESV)和射血分数(EF),并与传统左心室电影血管造影术获得的相同参数进行比较。第一组20例患者在静息状态下接受研究,第二组10例患者在以64瓦的工作负荷进行2分钟自行车运动期间,通过DSA和传统电影血管造影术进行研究。评估了三种不同的减法模式:(1)蒙片模式减法(MMS),(2)时间间隔差(TID)法,以及(3)MMS和TID的组合,称为MMS + TID法。采用MMS法时,静息状态下和运动期间的EDV、ESV和EF均获得了良好的相关性(r大于0.91)。TID法在静息状态下(r大于0.86)和运动期间(r大于0.79)仅显示出中等相关性。联合方法(MMS + TID)在静息状态下(r大于0.91)和运动期间(r大于0.91)获得了与MMS相似的结果。观察者间变异性表明,除运动期间的TID外,所有方法均具有高重复性。结论是,DSA不仅是静息状态下,而且也是运动期间测定左心室容积的准确技术。采用MMS或MMS + TID法可获得最佳结果,而采用MMS + TID法检测左心室轮廓更容易、更方便。

相似文献

3
Left ventricle evaluation by digital video subtraction angiocardiography.
Radiology. 1982 Aug;144(3):471-4. doi: 10.1148/radiology.144.3.7048415.
10
Exercise left ventriculography utilizing intravenous digital angiography.
J Am Coll Cardiol. 1983 Dec;2(6):1092-8. doi: 10.1016/s0735-1097(83)80335-0.

引用本文的文献

1
Comparison of digital with conventional ventriculography for quantitative right ventricular studies.
Cardiovasc Intervent Radiol. 1988;11(1):5-9. doi: 10.1007/BF02577015.
2
Left ventricular wall thickness measurements by magnetic resonance: a validation study.
Int J Card Imaging. 1991;7(1):31-41. doi: 10.1007/BF01797678.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验