Suppr超能文献

术中确定膝关节置换组件松动的新阈值:手法检查时可见的液体流动——一项德尔菲研究

Visible fluid motion on manipulation as the new threshold for intraoperatively determined knee arthroplasty component loosening: A Delphi study.

作者信息

Buijs George S, Kievit Arthur J, Walinga Alex B, Schafroth Matthias U, Hirschmann Michael T, Blankevoort Leendert

机构信息

Department of Orthopedic Surgery and Sport Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands.

Amsterdam Movement Sciences, Musculoskeletal Health, Amsterdam, The Netherlands.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2025 Jan;33(1):343-353. doi: 10.1002/ksa.12357. Epub 2024 Jul 15.

Abstract

PURPOSE

There is a lack of a clear, uniform definition for intraoperatively assessed component loosening of a knee arthroplasty component, complicating the interpretation and interchangeability of results of diagnostic studies using an intraoperative observation as the reference test. The purpose of this study was to establish a consensus among specialised knee revision surgeons regarding the definition of intraoperatively determined loosening of total or unicondylar knee arthroplasty components.

METHODS

Utilising the Delphi consensus method, an international panel of highly specialised knee revision surgeons was invited to participate in a three-round process. The initiation of the first round involved the exploration of possible criteria for intraoperatively determined loosening with open questions. The second round focused on rating these criteria importance on a five-point Likert scale. For the third round, criteria that reached consensus were summarised in consecutive definitions for intraoperatively determined loosening and proposed to the panel. Consensus was established when over 70% of participants agreed with a definition for intraoperatively determined loosening.

RESULTS

The 34 responding panel members described in total 60 different criteria in the first round of which 34 criteria received consensus in the second round. Summarising these criteria resulted in four different definitions as minimal requirements for intraoperatively determined loosening. Eighty-eight percent of the panel members agreed on defining a component as loose if there is visible fluid motion at the interface observed during specific movements or when gently applying direct force.

CONCLUSION

This study successfully established a consensus using a Delphi method among knee revision surgeons on the definition of intraoperatively determined component loosening. By agreeing on the visibility of fluid motion as new definition, this study provides a standardised reference for future diagnostic research. This definition will enhance the interpretability and interchangeability of future diagnostic studies evaluating knee arthroplasty component loosening.

LEVEL OF EVIDENCE

Level V.

摘要

目的

对于膝关节置换组件术中评估的组件松动,缺乏清晰、统一的定义,这使得以术中观察作为参考测试的诊断研究结果的解释和互换性变得复杂。本研究的目的是在专业的膝关节翻修外科医生中就术中确定的全膝关节或单髁膝关节置换组件松动的定义达成共识。

方法

采用德尔菲共识法,邀请国际上高度专业化的膝关节翻修外科医生组成的小组参与三轮过程。第一轮开始时通过开放式问题探索术中确定松动的可能标准。第二轮重点是以五点李克特量表对这些标准的重要性进行评分。在第三轮中,将达成共识的标准总结为术中确定松动的连续定义,并提交给该小组。当超过70%的参与者同意术中确定松动的定义时,即达成共识。

结果

34名回复的小组成员在第一轮中总共描述了60条不同的标准,其中34条标准在第二轮中获得了共识。总结这些标准得出了四种不同的定义,作为术中确定松动的最低要求。如果在特定运动期间或轻轻施加直接力时在界面处观察到可见的液体流动,则88%的小组成员同意将组件定义为松动。

结论

本研究通过德尔菲法成功地在膝关节翻修外科医生中就术中确定的组件松动的定义达成了共识。通过就液体流动的可见性作为新定义达成一致,本研究为未来的诊断研究提供了标准化参考。该定义将提高未来评估膝关节置换组件松动的诊断研究的可解释性和互换性。

证据水平

V级。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验