The use of an oral positive expiratory pressure device (oPEP) with sniff breathing (Sniff-PEP) mimics biphasic ventilation. Biphasic ventilation increases pulmonary blood flow and cardiac output in Fontan patients. The aim of this study was to assess the effect of Sniff-PEP on Fontan flow velocities. A single-center, pilot, prospective study was carried out in 15 subjects with Fontan circulation enrolled to use the oPEP device for 1 month. Subjects were instructed on Sniff-PEP and to use the device for 10-15 min 3-4 times a day. Measurements of flow velocity and cardiac output were measured via echocardiogram and quality of life assessments were performed at baseline and 4-6 weeks later. The mean age at enrollment was 19.9 ± 8.7 years (age range of 10-37 years). 7 patients (47%) had dominant left ventricle and 8 (53%) had an open fenestration. There was a statistically significant increase in flow velocities in the hepatic vein from 27.5 ± 7.6 to 35.1 ± 11.3 cm/s (p = 0.003), left pulmonary artery from 51.6 ± 16.6 to 57.6 ± 21.1 cm/s (p = 0.01), and right pulmonary artery from 43.1 ± 14.2 to 45.8 ± 17.2 cm/s (p = 0.04). With chronic use, the mean fenestration gradient slightly decreased from 4.5 ± 1.6 to 4.1 ± 1.9 mmHg but the difference was not statistically significant (p = 0.14). oPEP device therapy increased flow velocity in several areas in the Fontan circulation with acute use. Further studies are needed to assess the effects long term.Clinical Trial Registration: URL: https://clinicaltrials.gov . Unique identifier: NCT03251742.
使用带有嗅吸呼吸的口服呼气末正压装置(oPEP)(嗅吸 - PEP)可模拟双相通气。双相通气可增加Fontan患者的肺血流量和心输出量。本研究的目的是评估嗅吸 - PEP对Fontan血流速度的影响。对15名接受Fontan循环的受试者进行了一项单中心、试点、前瞻性研究,让他们使用oPEP装置1个月。指导受试者进行嗅吸 - PEP操作,并每天使用该装置3 - 4次,每次10 - 15分钟。通过超声心动图测量血流速度和心输出量,并在基线时以及4 - 6周后进行生活质量评估。入组时的平均年龄为19.9±8.7岁(年龄范围为10 - 37岁)。7名患者(47%)左心室占优势,8名患者(53%)有开放的卵圆孔未闭。肝静脉血流速度从27.5±7.6厘米/秒显著增加到35.1±11.3厘米/秒(p = 0.003),左肺动脉从51.6±16.6厘米/秒增加到57.6±21.1厘米/秒(p = 0.01),右肺动脉从43.1±14.2厘米/秒增加到45.8±17.2厘米/秒(p = 0.04)。长期使用后,平均卵圆孔未闭压差从4.5±1.6毫米汞柱略有下降至4.1±1.9毫米汞柱,但差异无统计学意义(p = 0.14)。急性使用oPEP装置治疗可增加Fontan循环中多个区域的血流速度。需要进一步研究来评估长期效果。临床试验注册:网址:https://clinicaltrials.gov 。唯一标识符:NCT03251742。