Suppr超能文献

新型弹弓式投掷训练器的专项力量训练对等速向心峰力矩的改善和肩部肌肉失衡的纠正:一项随机对照试验。

Isokinetic Peak Torque Improvement and Shoulder Muscle Ratios Imbalance Correction After Specific Strength Training on a New Ballistic Throwing Device: A Randomized Controlled Trial.

机构信息

Higher Institute of Sport and Physical Education of Ksar Said, Tunis, Tunisia.

Research Unit "Sport Sciences, Health and Movement," Higher Institute of Sports and Physical Education of Kef, University of Jendouba, Kef, Tunisia.

出版信息

J Sport Rehabil. 2024 Jul 19;33(6):423-436. doi: 10.1123/jsr.2023-0253. Print 2024 Aug 1.

Abstract

CONTEXT

The aim of this study was to investigate the effects of 8-week ballistic-strength-training program using a validated specific throwing device (ie, Arm/Shoulder Specific Strength Device), on isokinetic shoulders' rotation muscle-torques and ratios as well as range of motion in team handball players.

DESIGN

A repeated-measures experimental design with a randomized controlled trial was used.

METHODS

Twenty-six high-level competitive male U-19 team handball players were randomly assigned into training (TG, n = 15) and control (n = 11) groups. The TG undertook a twice a week for 8-week periodized throws program with an individually predetermined optimal load. The program incorporated shackled eccentric and concentric exercises using the Arm/Shoulder Specific Strength Device. Peak torques, functional, and conventional ratios for both arms at different angular velocities (60°·s-1, 180°·s-1, and 300°·s-1) were assessed over time and between groups, using an isokinetic dynamometer.

RESULTS

A significant improvement for TG (P < .01; d = 1.13 [moderate]; +20.2%) of the concentric peak torques for dominant arm in external rotation was observed at 300°·s-1. Significant (P < .05-.01) increases were also noted for nondominant arm at the 3 studied angular velocities. In addition, 300°·s-1 eccentric peak torques of the dominant arm and nondominant arm have significantly improved for both external and internal rotations (P < .05; d = .99 [moderate] and d = 1.21 [large]; +15.7% and + 17.9%, respectively) with small changes at the other angular assessed velocities. Posttraining, TG's dominant arm showed significant improvements (P < .05-.01) in functional and conventional ratios at all velocities. Notably, significant differences (P < .05-.01) were observed at 60°·s-1 and across all velocities when comparing the TG with the control group. TG showed significant increase for internal rotation and external rotation shoulder range of motions (P < .05; d = 1.22-1.27 [large]), +5.0% and +7.7%, respectively).

CONCLUSIONS

The specific 8-week throwing training program on the Arm/Shoulder Specific Strength Device showed significant performance improvements in almost all assessed isokinetic concentric and eccentric peak torques as well as internal and external range of motion increase for both arms while ensuring rotator cuff torque ratios and shoulder mobility in team handball real sport-specific condition.

摘要

背景

本研究旨在探究使用经过验证的特定投掷装置(即臂肩专项力量训练装置)进行 8 周弹道强度训练对团队手球运动员等速肩部旋转肌肉扭矩和比值以及运动范围的影响。

设计

采用重复测量实验设计和随机对照试验。

方法

26 名高水平竞技性 U-19 男子手球运动员被随机分为训练组(TG,n=15)和对照组(n=11)。TG 进行了为期 8 周的周期性投掷计划,每周两次,采用个体化最佳负荷。该计划采用 Arm/Shoulder Specific Strength Device 进行束缚性离心和向心运动。使用等速测力计评估两组在不同角速度(60°·s-1、180°·s-1 和 300°·s-1)下的双侧手臂的峰值扭矩、功能和常规比值。

结果

TG 的优势手臂外旋的 300°·s-1 时的向心峰值扭矩显著提高(P <.01;d = 1.13 [中等];+20.2%)。还观察到非优势手臂在 3 个研究角速度下的显著增加(P <.05-.01)。此外,优势臂和非优势臂的 300°·s-1 离心峰值扭矩在内外旋方向均有显著改善(P <.05;d =.99 [中等]和 d = 1.21 [大];+15.7%和+17.9%),而在其他角速度下的变化较小。训练后,TG 的优势手臂在所有角速度下的功能和常规比值均有显著提高(P <.05-.01)。值得注意的是,与对照组相比,TG 在 60°·s-1 和所有角速度下均有显著差异(P <.05-.01)。TG 的内旋和外旋肩部运动范围也有显著增加(P <.05;d = 1.22-1.27 [大];+5.0%和+7.7%)。

结论

使用 Arm/Shoulder Specific Strength Device 进行的 8 周专项投掷训练计划在手球专项运动条件下,几乎所有评估的等速向心和离心峰值扭矩以及双侧手臂的内外旋运动范围都有显著提高,同时确保了肩袖扭矩比和肩部活动度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验