Volz Frederik, Schmutterer Johannes Maximilian, Vockrodt Tanja Stephanie, Zablotski Yury, Lauer Susanne Katja
LMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universität München, Veterinärstraße 13, 80539, Munich, Germany.
Tierklinik Dinkelsbühl, Heininger-Ring 17, 91550, Dinkelsbühl, Germany.
BMC Vet Res. 2024 Aug 1;20(1):339. doi: 10.1186/s12917-024-04206-5.
Goniometry can be performed clinically in dogs with cranial cruciate ligament disease (CCLD). The purpose of this study was (1) to compare reliability of stifle goniometry in dogs with CCLD and healthy dogs and (2) to investigate the effect of compliance on measurements. Dogs presented for surgical intervention for CCLD (CCL-Dogs; n = 15) and orthopedically healthy dogs (C-Dogs; n = 11) were enrolled in this prospective randomized controlled trial. In each dog, three observers randomly measured maximum stifle flexion (mSF) and maximum stifle extension (mSE) three times with a standard goniometer with the scale covered, while dog compliance was scored (Scores: C0: excellent - C4: poor). Intraclass correlation coefficient (ICC) was calculated for intra-/interobserver reliability. Effects on measurements were evaluated with mixed-effect models (MEM).
Maximum stifle extension and mSE-compliance were significantly decreased in CCL-Dogs compared to C-Dogs (p ≤ 0.004), but mSF and mSF-compliance did not differ between groups. Intraobserver reliability was excellent for all dogs during mSE (ICC:0.75-0.99) and mSF (ICC:0.89-0.99). Interobserver reliability was excellent for mSF in both groups (ICC: C-Dogs:0.84, CCL-Dogs:0.9) and for mSE in CCL-Dogs (ICC:0.94) but only fair for mSE in C-Dogs (ICC:0.58). Robust MEM showed that the combined average of all mSE measurements of all three observers was affected by compliance in both groups (p < 0.001). This effect was not observed for single mSE-measurements by themselves.
The results of this study indicate that compliance may affect goniometric stifle extension measurements in healthy and CCLD dogs. In a clinical setting, intra-/interobserver reliability was excellent for all measurements except for maximum stifle extension in healthy dogs.
在患有前十字韧带疾病(CCLD)的犬只中可进行临床测角。本研究的目的是:(1)比较CCLD犬与健康犬的 stifle 测角的可靠性;(2)研究依从性对测量的影响。因CCLD接受手术干预的犬(CCL-犬;n = 15)和骨科健康犬(C-犬;n = 11)被纳入这项前瞻性随机对照试验。在每只犬中,三名观察者在覆盖刻度的标准测角仪下,对最大 stifle 屈曲(mSF)和最大 stifle 伸展(mSE)随机测量三次,同时对犬的依从性进行评分(评分:C0:优秀 - C4:差)。计算组内/组间相关系数(ICC)以评估观察者内/间的可靠性。使用混合效应模型(MEM)评估对测量的影响。
与C-犬相比,CCL-犬的最大 stifle 伸展和 mSE-依从性显著降低(p≤0.004),但两组间的 mSF 和 mSF-依从性无差异。在所有犬中,观察者内可靠性在 mSE(ICC:0.75 - 0.99)和 mSF(ICC:0.89 - 0.99)时均极佳。两组中 mSF 的观察者间可靠性均极佳(ICC:C-犬:0.84,CCL-犬:0.9),CCL-犬中 mSE 的观察者间可靠性极佳(ICC:0.94),但C-犬中 mSE 的观察者间可靠性仅为中等(ICC:0.58)。稳健的 MEM 显示,两组中所有三名观察者的所有 mSE 测量的综合平均值受依从性影响(p < 0.001)。单个 mSE 测量本身未观察到这种影响。
本研究结果表明,依从性可能会影响健康犬和CCLD犬的测角 stifle 伸展测量。在临床环境中,除健康犬的最大 stifle 伸展外,所有测量的观察者内/间可靠性均极佳。