Savić Ivan M, Savić Gajić Ivana M, Gajić Dragoljub G
Faculty of Technology in Leskovac, University of Nis, Bulevar Oslobodjenja 124, 16000 Leskovac, Serbia.
School of Electrical Engineering, University of Belgrade, Bulevar Kralja Aleksandra 73, 11000 Belgrade, Serbia.
Foods. 2024 Jul 24;13(15):2333. doi: 10.3390/foods13152333.
This study aimed to develop a fast procedure for caffeine extraction from roasted coffee beans. The microwave-assisted extraction was carried out in the microwave oven with an operating frequency of 2450 MHz. The response surface methodology based on a Box-Behnken design was used to model and optimize the extraction process. Among the analyzed extraction parameters (factors), the influence of extraction time (2-6 min), liquid-to-solid ratio (5-15 mL/g), and microwave power (336-595 W) were considered, while the yield of extracted caffeine was observed as the response of the system. Water was used as the solvent of choice for the extraction of caffeine. The optimum conditions were as follows: extraction time, 2 min; liquid-to-solid ratio, 15 mL/g; and microwave power, 500 W. In this optimized condition, the expected extraction yield of caffeine was 1.01 g/100 g dry weight (value confirmed by experimental assays). The total energy consumed of 1.7 kWh/100 g of purified caffeine indicated a more energy-efficient procedure by about 1200-15,000 times than the reported procedures. This study showed that caffeine can be quantitatively extracted from roasted coffee beans through a green approach and that the isolated caffeine has a high purity degree, which was confirmed by the UHPLC-ESI-MS/MS method. With this quality, isolated caffeine could be further used as an active ingredient in the food industry, while for pharmaceutical purposes, it must be further purified.
本研究旨在开发一种从烘焙咖啡豆中快速提取咖啡因的方法。微波辅助萃取在工作频率为2450 MHz的微波炉中进行。基于Box-Behnken设计的响应面法用于对萃取过程进行建模和优化。在分析的萃取参数(因素)中,考虑了萃取时间(2 - 6分钟)、液固比(5 - 15 mL/g)和微波功率(336 - 595 W)的影响,同时观察提取咖啡因的产率作为系统的响应。水被用作萃取咖啡因的首选溶剂。最佳条件如下:萃取时间2分钟;液固比15 mL/g;微波功率500 W。在此优化条件下,咖啡因的预期提取产率为1.01 g/100 g干重(该值经实验测定确认)。每100 g纯化咖啡因消耗的总能量为1.7 kWh,表明该方法比已报道的方法节能约1200 - 15000倍。本研究表明,咖啡因可以通过绿色方法从烘焙咖啡豆中定量提取,且分离出的咖啡因具有高纯度,这通过UHPLC-ESI-MS/MS方法得到证实。凭借这种品质,分离出的咖啡因可进一步用作食品工业中的活性成分,而用于制药目的时,必须进一步纯化。