Abstract

During one year period our laboratory carried out 859 hemocultures. These have been evaluated with two methods: a conventional biphasic method (Castaneda bottles), and the automated radiometric method (Bactec System). 185 cultures were obtained with one or both methods. Of these 3.5% were considered contaminated, therefore the clinically significant isolation rate was 16.2%. Of these 86.4% was recovered by biphasic system and 79.8% by Bactec System. The recovery time to positivity and spectrum of isolates were similar for the two methods. Although there were substantially more contaminants isolated in the Vacutainer-Bactec System.

摘要

在一年的时间里,我们实验室进行了859次血培养。这些血培养用两种方法进行评估:传统的双相培养法(卡氏瓶法)和自动放射测量法(Bactec系统)。通过一种或两种方法获得了185份培养物。其中3.5%被认为是污染菌,因此临床显著分离率为16.2%。其中86.4%通过双相系统获得,79.8%通过Bactec系统获得。两种方法的阳性恢复时间和分离菌株谱相似。尽管在真空采血管-Bactec系统中分离出的污染菌明显更多。