Department of Endodontics, Faculty of Dentistry, Gaziantep University.
J Oral Sci. 2024 Oct 16;66(4):226-230. doi: 10.2334/josnusd.24-0015. Epub 2024 Aug 20.
This study evaluated transportation and extruded debris during preparation using different instruments.
Sixty resin blocks with S-shaped canals and 60 extracted teeth were separated into four groups (n = 15), which were instrumented with Reciproc Blue, XP-endo Shaper, WaveOne Gold, and Twisted File Adaptive. For evaluating transportation, pre- and post-preparation images were obtained under a stereomicroscope and superimposed with digital software. The distance between the inner and outer canal walls was measured. For the evaluation of debris extrusion, the samples were placed in Eppendorf tubes and instrumented using one of the four rotary files. The initial weight was subtracted from the post-instrumentation weight to determine the amount of extruded debris. The Kruskal-Wallis and Dunn multiple tests were performed.
For transportation, no significant difference was found between the XP-endo Shaper-Twisted File Adaptive systems and between Reciproc Blue-WaveOne Gold groups (P > 0.05). The XP-endo Shaper and Twisted File Adaptive techniques led to significantly less transportation compared to the other systems (P < 0.05). Regarding debris extrusion, the XP-endo Shaper system extruded significantly less debris than the other groups (P < 0.05).
XP-endo Shaper extruded less debris compared to other groups, while XP-endo Shaper and Twisted File Adaptive caused less transportation than other files.
本研究评估了不同器械在预备过程中的输送和挤出的碎屑。
将 60 个具有 S 形根管的树脂块和 60 颗拔出的牙齿分为四组(n = 15),分别用 Reciproc Blue、XP-endo Shaper、WaveOne Gold 和 Twisted File Adaptive 进行器械预备。为评估输送,在立体显微镜下获得预备前后的图像,并使用数字软件进行叠加。测量内、外根管壁之间的距离。为评估碎屑挤出,将样本放入 Eppendorf 管中,用四种旋转锉中的一种进行器械预备。从器械预备后的重量中减去初始重量,以确定挤出的碎屑量。采用 Kruskal-Wallis 和 Dunn 多重检验进行分析。
在输送方面,XP-endo Shaper-Twisted File Adaptive 系统和 Reciproc Blue-WaveOne Gold 组之间没有显著差异(P > 0.05)。与其他系统相比,XP-endo Shaper 和 Twisted File Adaptive 技术导致的输送明显较少(P < 0.05)。关于碎屑挤出,XP-endo Shaper 系统挤出的碎屑明显少于其他组(P < 0.05)。
与其他组相比,XP-endo Shaper 挤出的碎屑较少,而 XP-endo Shaper 和 Twisted File Adaptive 比其他锉引起的输送较少。