Suppr超能文献

在两个时间间隔对森通强效型与等效强效型以及两种硅酸钙水门汀进行界面评估。

Interfacial assessment of cention forte vs. equia forte and two forms of calcium silicate cements at two time intervals.

作者信息

Abdelkafy Heba, Salem Nada A, Marzouk Rasha Mohamed, Eldehna Alaa M

机构信息

Department of Endodontic, Faculty of Dental Medicine for Girls, Al-Azhar University, Cairo, Egypt.

Department of Pediatric Dentistry and Dental Public Health - Faculty of Dentistry- October 6 University, Cairo, Egypt.

出版信息

BDJ Open. 2024 Aug 24;10(1):68. doi: 10.1038/s41405-024-00252-1.

Abstract

AIM

Assessment of interfacial gaps and mechanical impact of the materials layering between Cention Forte and Equia Forte restorations with two forms of Calcium Silicate Cements (CSCs) at the interfacial surface at two-time intervals.

METHODOLOGY

Six groups of 72 primary molars were categorized by restorative material type and CSCs: Cention Forte(C), Cention Forte without primer (Cx), and Equia Forte (EQ). All were applied over MTA Angelus powder (M) or Bio-C Repair putty (P). Restorative materials were applied immediately (subgroup A) or delayed (Subgroup B). SEM was used to detect interface gaps. EDX measured element migration from the interface at specific distances. Vickers Microhardness Tester assessed microhardness.

RESULTS

Regarding SEM, there were no gaps between CSCs interfaces of both types (Powder and Putty) with all restorations at two-time intervals. Microhardness, there was a statistically nonsignificant difference between subgroups A & B in all groups except at 200 µm in the Cention groups (subgroup A) was significantly lower than (subgroup B) (P = 0.002, 0.03) respectively. At 400 µm in the MTA Angelus powder Group Cx, subgroup A was significantly higher than subgroup B (P = 0.003*). While Bio-C Repair putty in Group EQ (subgroup A) was significantly higher than (Subgroup B) (P < 0.0001*).

CONCLUSIONS

The delayed application of Cention Forte over two types of CSCs is useful in getting the maximum HV and, in turn, the long survival rate of the filling. Immediate application of Cention Forte without primer is better over both types of CSCs. The delayed application of Equia Forte over MTA angelus powder is more considerable.

摘要

目的

评估在两个时间间隔下,两种形式的硅酸钙水门汀(CSCs)在Cention Forte和Equia Forte修复体之间分层材料的界面间隙和机械影响。

方法

根据修复材料类型和CSCs将72颗乳磨牙分为六组:Cention Forte(C)、无底漆的Cention Forte(Cx)和Equia Forte(EQ)。所有材料均应用于MTA Angelus粉末(M)或Bio-C Repair腻子(P)上。修复材料立即应用(A亚组)或延迟应用(B亚组)。使用扫描电子显微镜(SEM)检测界面间隙。能量色散X射线光谱仪(EDX)测量特定距离处界面的元素迁移。维氏显微硬度计评估显微硬度。

结果

关于SEM,在两个时间间隔下,两种类型(粉末和腻子)的CSCs与所有修复体的界面之间均无间隙。在显微硬度方面,除了在Cention组中200µm处(A亚组)显著低于(B亚组)(P分别为0.002、0.03)外,所有组的A亚组和B亚组之间在统计学上无显著差异。在MTA Angelus粉末组Cx的400µm处,A亚组显著高于B亚组(P = 0.003*)。而在EQ组的Bio-C Repair腻子中(A亚组)显著高于(B亚组)(P < 0.0001*)。

结论

在两种类型的CSCs上延迟应用Cention Forte有助于获得最大的维氏硬度,进而提高充填物的长期存活率。无底漆立即应用Cention Forte在两种类型的CSCs上效果更好。在MTA angelus粉末上延迟应用Equia Forte更值得考虑。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/968a/11344803/44385f9fc370/41405_2024_252_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验