Abstract

BACKGROUND

Left Bundle Branch Area Pacing (LBBaP) is a cardiac pacing technique designed to mimic the natural conduction system of the heart. Traditional right ventricular apical pacing has been associated with increased risks of heart failure and atrial fibrillation. This study investigates the stability and safety of LBBaP using the Selectra 3D sheath (Biotronik) with an inclined angle for implanting the Solia S lead (Biotronik, SE & Co, KG).

METHODS

A single-center retrospective study was conducted on 25 patients who underwent LBBaP implantation using the Selectra 3D sheath at our hospital. The procedure involved inserting the Solia S lead into the interventricular septum at an inclined angle. Surgical and postoperative data were collected, including the success rate, depth and angle of electrode insertion, complications, and follow-up data.

RESULTS

The success rate of LBBaP implantation was 92%. The length of electrode insertion into the interventricular septum ranged from 12 to 23.0 mm, with an average of 18.1 ± 3.08 mm. The angle formed between the electrode and the septum ranged from 0° to 57.3°, with an average of 35.14°±14.31°. During the 3-month follow-up period, pacing parameters remained stable, and no complications were reported.

CONCLUSIONS

LBBaP implantation using the Selectra 3D sheath with an inclined angle for the Solia S implantation demonstrates stability and safety. The procedure boasts a high success rate and offers an effective option for LBBaP implantation.

摘要

背景

左束支区域起搏(LBBaP)是一种旨在模拟心脏自然传导系统的心脏起搏技术。传统的右心室心尖部起搏与心力衰竭和心房颤动的风险增加有关。本研究使用带有倾斜角度的 Selectra 3D 鞘(Biotronik)和 Solia S 导线(Biotronik,SE & Co,KG)植入,调查 LBBaP 的稳定性和安全性。

方法

对在我院行 LBBaP 植入术的 25 例患者进行了单中心回顾性研究。该手术过程包括将 Solia S 导线以倾斜角度插入室间隔。收集了手术和术后数据,包括成功率、电极插入的深度和角度、并发症和随访数据。

结果

LBBaP 植入的成功率为 92%。电极插入室间隔的长度为 12 至 23.0mm,平均为 18.1±3.08mm。电极与间隔之间形成的角度为 0°至 57.3°,平均为 35.14°±14.31°。在 3 个月的随访期间,起搏参数保持稳定,未报告并发症。

结论

使用带有倾斜角度的 Selectra 3D 鞘和 Solia S 植入物进行 LBBaP 植入术显示出稳定性和安全性。该手术成功率高,为 LBBaP 植入提供了一种有效的选择。