Department of Pediatric Dentistry, Faculty of Dentistry, İzmir Tınaztepe University, İzmir, Turkey.
Department of Pediatric Dentistry, Faculty of Dentistry, Ege University, Erzene Mah., Ankara Cad. No:172/109, İzmir, Turkey.
Clin Oral Investig. 2024 Aug 28;28(9):503. doi: 10.1007/s00784-024-05901-1.
The aim of this study was to investigate the effect of remineralization agents such as fluoride varnish and P-4, alone and in combination with Er: YAG laser, on in-vitro hard tissue repair in artificial enamel lesions.
A total of sixty enamel surfaces of 4 × 5 mm in size were created on both the buccal and lingual sides of thirty extracted wisdom teeth. Remineralization agents were applied to the specimens that were grouped as follows: Group 1, control; Group 2, fluoride varnish (FV); Group 3, P-4; Group 4, laser; Group 5, laser + FV; and Group 6, laser + P-4. The fluorescence level was determined with DiagnoDent. The enamel mineral density, area and volume, and caries lesion area and volume were determined with micro-computed tomography (µCT), surface features were evaluated using scanning electron microscopy (SEM), and elemental analysis was performed using energy dispersive x-ray spectroscopy (EDS) .
For specimens treated only with self-assembling peptide P-4, the caries lesion area (mm) values were 38.19 and 21.62, and the caries lesion volume (mm) values were 6.27 and 2.99, respectively for pre- and post-treatment. In combination usage of self-assembling peptide P-4 and laser, the caries lesion area (mm) values were 38.39 and 16.91, and the caries lesion volume (mm) values were 11.15 and 3.64, respectively for pre- and post-treatment. In the application of the P-4 alone and in combination with laser, there was a statistically significant decrease in DiagnoDent values, an increase in enamel volume(mm),enamel area(mm) and mineral density(g/cm) values and a decrease in caries lesion volume(mm) and area(mm) obtained by µCT, and an increase in %Ca and %F values obtained by SEM/EDS analysis (p < 0.05). It was discovered that the samples treated with P-4 had a considerably higher rise in the Ca/P ratio than the samples treated with FV (p < 0.05). The calcium content increased significantly more when P-4 application was combined with laser irradiation (p < 0.05).
The combined use of self-assembling peptide P-4 and laser accelerated the remineralization process and increased the remineralization capacity.
FV and P-4, alone or in combination with laser, can be successfully used as remineralization agents in initial enamel caries.
本研究旨在探讨再矿化剂(如氟漆和 P-4)单独及联合 Er:YAG 激光对人工釉质损伤的体外硬组织修复效果。
从 30 颗拔出的智齿的颊侧和舌侧各制备 60 个大小为 4×5mm 的釉质表面。将标本分为以下几组:第 1 组为对照组;第 2 组为氟漆(FV)组;第 3 组为 P-4 组;第 4 组为激光组;第 5 组为激光+FV 组;第 6 组为激光+P-4 组。采用 DiagnoDent 测定荧光水平。采用微计算机断层扫描(µCT)测定釉质矿物密度、面积和体积以及龋损面积和体积,采用扫描电子显微镜(SEM)评估表面特征,采用能谱仪(EDS)进行元素分析。
仅用自组装肽 P-4 处理的标本,治疗前后龋损面积(mm)值分别为 38.19 和 21.62,龋损体积(mm)值分别为 6.27 和 2.99。自组装肽 P-4 与激光联合使用时,治疗前后龋损面积(mm)值分别为 38.39 和 16.91,龋损体积(mm)值分别为 11.15 和 3.64。单独应用 P-4 及联合激光应用后,DiagnoDent 值、釉质体积(mm)、釉质面积(mm)、矿物密度(g/cm)值均显著升高,龋损体积(mm)和面积(mm)值均显著降低,SEM/EDS 分析的%Ca 和%F 值升高(p<0.05)。与 FV 处理的标本相比,用 P-4 处理的标本的 Ca/P 比值明显升高(p<0.05)。当 P-4 与激光联合应用时,钙含量显著增加(p<0.05)。
自组装肽 P-4 联合激光可加速再矿化过程,提高再矿化能力。
FV 和 P-4 单独或联合激光可作为初始釉质龋的再矿化剂。