The speedometer is widely used to evaluate swimming velocity but has some constraints. With the constant development of inertial units (IMUs), it is expected that they will become a good alternative to the speedometer. This study aimed to compare the data retrieved by an IMU and a speedometer when breaststroke is performed at maximum speed. Sixteen swimmers, nine males and seven females (20.3 ± 3.3 vs. 18.7 ± 1.1 years old, 65.8 ± 11.2 vs. 57.7 ± 9.1 kg of body mass and 1.75 ± 0.07 vs. 1.61 ± 0.10 m of height, respectively), performed 4 × 25 m of breaststroke sprint. They were equipped with an IMU fixed to the sacrum and with the line of an electromechanical speedometer (acquisition frequency of 50 Hz) fixed at the central point in the lumbar region. Statistical parametric mapping was used to compare the velocity curves, IBM SPSS was used for descriptive statistics and Bland-Altman plots were used for agreement of measurements. The results show that the IMU and speedometer do not show similar patterns, and the velocity values measured by the IMU are lower ( < 0.001). Bland-Altman plots presented a larger bias in terms of coefficient of variation and intracycle velocity variation. It can be concluded that IMUs and speedometers are not substitutes for each other as methods for evaluating intracycle velocity variations.
速度计被广泛用于评估游泳速度,但存在一些局限性。随着惯性测量单元(IMU)的不断发展,预计它们将成为速度计的良好替代品。本研究旨在比较在进行最大速度蛙泳时,IMU和速度计获取的数据。16名游泳运动员,9名男性和7名女性(年龄分别为20.3±3.3岁和18.7±1.1岁,体重分别为65.8±11.2千克和57.7±9.1千克,身高分别为1.75±0.07米和1.61±0.10米)进行了4×25米的蛙泳冲刺。他们佩戴了一个固定在骶骨上的IMU和一个固定在腰椎区域中心点的机电速度计线路(采集频率为50赫兹)。使用统计参数映射来比较速度曲线,使用IBM SPSS进行描述性统计,并使用布兰德-奥特曼图来评估测量的一致性。结果表明,IMU和速度计显示出不同的模式,并且IMU测量的速度值较低(<0.001)。布兰德-奥特曼图在变异系数和周期内速度变化方面呈现出较大的偏差。可以得出结论,IMU和速度计作为评估周期内速度变化的方法不能相互替代。