De Klerk E, Anderson R
J Clin Microbiol. 1985 Mar;21(3):381-6. doi: 10.1128/jcm.21.3.381-386.1985.
An enzyme-linked immunosorbent assay was adapted to measure total and Brucella abortus-specific immunoglobulin M antibodies. The results were compared with those of conventional serological tests for B. abortus antibody on the sera of a number of normal controls, apparently healthy occupationally exposed workers, and patients with suspected acute brucellosis. Relative to other tests, the B. abortus enzyme-linked immunosorbent assay was found to be both highly sensitive and highly specific. The serological results obtained in occupationally exposed workers indicate a higher "normal range" for this group and therefore a possibility of false-positive results and overdiagnosis. It is therefore important to establish a separate "normal range" for occupationally exposed workers. Investigation of patients with acute brucellosis showed that the enzyme-linked immunosorbent assay for immunoglobulin M was the most sensitive serodiagnostic test and was likely to be of value in the serodiagnosis of acute brucellosis in occupationally exposed workers.
采用酶联免疫吸附测定法来检测总免疫球蛋白M抗体和布鲁氏菌流产菌特异性免疫球蛋白M抗体。将结果与多项常规血清学检测布鲁氏菌流产菌抗体的结果进行比较,这些常规检测针对的是一些正常对照者、表面健康的职业暴露工人以及疑似急性布鲁氏菌病患者的血清。相对于其他检测方法,发现布鲁氏菌流产菌酶联免疫吸附测定法具有高度敏感性和高度特异性。职业暴露工人的血清学结果表明该组的“正常范围”更高,因此存在假阳性结果和过度诊断的可能性。所以为职业暴露工人建立一个单独的“正常范围”很重要。对急性布鲁氏菌病患者的调查显示,免疫球蛋白M酶联免疫吸附测定法是最敏感的血清诊断检测方法,可能对职业暴露工人急性布鲁氏菌病的血清诊断有价值。