Suppr超能文献

嵌入式惯性测量单元鞋垫测量时空跑步参数的有效性和重测信度。

Validity and Test-Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles.

机构信息

CHU Dijon-Bourgogne, Centre d'Investigation Clinique, Module Plurithématique, Plateforme d'Investigation Technologique, 21000 Dijon, France.

INSERM, CIC 1432, Module Plurithématique, Plateforme d'Investigation Technologique, 21000 Dijon, France.

出版信息

Sensors (Basel). 2024 Aug 22;24(16):5435. doi: 10.3390/s24165435.

Abstract

Running is the basis of many sports and has highly beneficial effects on health. To increase the understanding of running, DSPro insoles were developed to collect running parameters during tasks. However, no validation has been carried out for running gait analysis. The aims of this study were to assess the test-retest reliability and criterion validity of running gait parameters from DSPro insoles compared to a motion-capture system. Equipped with DSPro insoles, a running gait analysis was performed on 30 healthy participants during overground and treadmill running using a motion-capture system. Using an intraclass correlation coefficient (ICC), the criterion validity and test-retest reliability of spatiotemporal parameters were calculated. The test-retest reliability shows moderate to excellent ICC values (ICC > 0.50) except for propulsion time during overground running at a fast speed with the motion-capture system. The criterion validity highlights a validation of running parameters regardless of speeds (ICC > 0.70). This present study validates the good criterion validity and test-retest reliability of DSPro insoles for measuring spatiotemporal running gait parameters. Without the constraints of a 3D motion-capture system, such insoles seem to be helpful and relevant for improving the care management of active patients or following running performance in sports contexts.

摘要

跑步是许多运动的基础,对健康有非常有益的影响。为了增加对跑步的了解,DSPro 鞋垫被开发出来,以在任务期间收集跑步参数。然而,对于跑步步态分析,尚未进行验证。本研究的目的是评估 DSPro 鞋垫与运动捕捉系统相比,在跑步步态参数的测试-重测信度和标准效度。在配备了 DSPro 鞋垫的情况下,30 名健康参与者在地面和跑步机上跑步时,使用运动捕捉系统进行了跑步步态分析。使用组内相关系数(ICC),计算了时空参数的标准效度和测试-重测信度。除了在运动捕捉系统上以高速进行地面跑步时的推进时间外,测试-重测信度显示出中等至极好的 ICC 值(ICC>0.50)。标准效度强调了无论速度如何,跑步参数的验证(ICC>0.70)。本研究验证了 DSPro 鞋垫测量时空跑步步态参数的良好标准效度和测试-重测信度。没有 3D 运动捕捉系统的限制,这种鞋垫似乎有助于改善活跃患者的护理管理或在运动环境中跟踪跑步表现。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/188a/11359420/1f183e0b4853/sensors-24-05435-g001.jpg