跑步过程中下肢运动学方面惯性测量单元的效度和信度:一项系统评价与荟萃分析

Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis.

作者信息

Zeng Ziwei, Liu Yue, Hu Xiaoyue, Tang Meihua, Wang Lin

机构信息

School of Kinesiology, Shanghai University of Sport, Shanghai, China.

出版信息

Sports Med Open. 2022 Jun 27;8(1):86. doi: 10.1186/s40798-022-00477-0.

Abstract

BACKGROUND

Inertial measurement units (IMUs) are useful in monitoring running and alerting running-related injuries in various sports settings. However, the quantitative summaries of the validity and reliability of the measurements from IMUs during running are still lacking. The purpose of this review was to investigate the concurrent validity and test-retest reliability of IMUs for measuring gait spatiotemporal outcomes and lower extremity kinematics of health adults during running.

METHODS

PubMed, CINAHL, Embase, Scopus and Web of Science electronic databases were searched from inception until September 2021. The inclusion criteria were as follows: (1) evaluated the validity or reliability of measurements from IMUs, (2) measured specific kinematic outcomes, (3) compared measurements using IMUs with those obtained using reference systems, (4) collected data during running, (5) assessed human beings and (6) were published in English. Eligible articles were reviewed using a modified quality assessment. A meta-analysis was performed to assess the pooled correlation coefficients of validity and reliability.

RESULTS

Twenty-five articles were included in the systematic review, and data from 12 were pooled for meta-analysis. The methodological quality of studies ranged from low to moderate. Concurrent validity is excellent for stride length (intraclass correlation coefficient (ICC) (95% confidence interval (CI)) = 0.937 (0.859, 0.972), p < 0.001), step frequency (ICC (95% CI) = 0.926 (0.896, 0.948), r (95% CI) = 0.989 (0.957, 0.997), p  < 0.001) and ankle angle in the sagittal plane (r (95% CI) = 0.939 (0.544, 0.993), p = 0.002), moderate to excellent for stance time (ICC (95% CI) = 0.664 (0.354, 0.845), r (95% CI) = 0.811 (0.701, 0.881), p < 0.001) and good for running speed (ICC (95% CI) = 0.848 (0.523, 0.958), p = 0.0003). The summary Fisher's Z value of flight time was not statistically significant (p = 0.13). Similarly, the stance time showed excellent test-retest reliability (ICC (95% CI) = 0.954 (0.903, 0.978), p < 0.001) and step frequency showed good test-retest reliability (ICC (95% CI) = 0.896 (0.837, 0.933), p < 0.001).

CONCLUSIONS

Findings in the current review support IMUs measurement of running gait spatiotemporal parameters, but IMUs measurement of running kinematics on lower extremity joints needs to be reported with caution in healthy adults.

TRIAL REGISTRATION

PROSPERO Registration Number: CRD42021279395.

摘要

背景

惯性测量单元(IMU)在各种运动场景中对监测跑步及警示与跑步相关的损伤方面很有用。然而,目前仍缺乏关于跑步过程中IMU测量有效性和可靠性的定量总结。本综述的目的是研究IMU在测量健康成年人跑步时的步态时空参数和下肢运动学方面的同时效度和重测信度。

方法

检索了PubMed、CINAHL、Embase、Scopus和Web of Science电子数据库,检索时间从建库至2021年9月。纳入标准如下:(1)评估IMU测量的有效性或可靠性;(2)测量特定的运动学结果;(3)将IMU的测量结果与使用参考系统获得的结果进行比较;(4)在跑步过程中收集数据;(5)评估人类;(6)以英文发表。使用改良的质量评估方法对符合条件的文章进行综述。进行荟萃分析以评估有效性和可靠性的合并相关系数。

结果

系统综述纳入了25篇文章,其中12篇的数据用于荟萃分析。研究的方法学质量从低到中等。步幅的同时效度极佳(组内相关系数(ICC)(95%置信区间(CI))=0.937(0.859,0.972),p<0.001),步频(ICC(95%CI)=0.926(0.896,0.948),r(95%CI)=0.989(0.957,0.997),p<0.001)和矢状面踝关节角度(r(95%CI)=0.939(0.544,0.993),p=0.002)的同时效度为中等至极佳,站立时间的同时效度为中等至优秀(ICC(95%CI)=0.664(0.354,0.845),r(95%CI)=0.811(0.701,0.881),p<0.001),跑步速度的同时效度良好(ICC(95%CI)=0.848(0.523,0.958),p=0.0003)。飞行时间的汇总费舍尔Z值无统计学意义(p=0.13)。同样,站立时间显示出极佳的重测信度(ICC(95%CI)=0.954(0.903,0.978),p<0.001),步频显示出良好的重测信度(ICC(95%CI)=0.896(0.837,0.933),p<0.001)。

结论

本综述的结果支持IMU对跑步步态时空参数的测量,但在健康成年人中,IMU对下肢关节跑步运动学的测量结果报告时需谨慎。

试验注册

PROSPERO注册号:CRD42021279395。