Suppr超能文献

8.5毫米长的牙种植体采用夹板式或单颗种植体修复的分析:一项15年的前瞻性研究。

Analysis of 8.5 mm Long Dental Implants Provided with Splinted or Solitary Implant Restorations: A 15-Year Prospective Study.

作者信息

Hakkers Jarno, Telleman Gerdien, de Waal Yvonne C M, Gareb Barzi, Vissink Arjan, Raghoebar Gerry M, Meijer Henny J A

机构信息

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, 9700 RB Groningen, The Netherlands.

Department of Periodontology, Center for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, 9713 GZ Groningen, The Netherlands.

出版信息

J Clin Med. 2024 Aug 30;13(17):5162. doi: 10.3390/jcm13175162.

Abstract

The long-term effects of implant properties, such as implant length, platform switch, and crown splinting, on peri-implant health require more investigation. Therefore, the aim was to assess the long-term peri-implant health and patient satisfaction in a patient cohort, obtained from two prospective randomized controlled trials, who received 8.5 mm long dental implants, with either splinted or solitary suprastructures and with or without a platform switch, over a period of 15 years. One hundred and twenty-two patients received either one or two 8.5 mm long dental implants (223 dental implants) with and without platform switch, restored with either a solitary ( = 89) or a splinted ( = 134) restoration in the posterior region. Clinical and radiographical parameters and patient satisfaction were prospectively recorded at 1 month, and 1, 5, and 15 years after the placement of the restoration. Patient satisfaction was recorded with a self-administered questionnaire using a 5-point scale and a visual analog scale (0-10). Eighty-one patients with one hundred and fifty-four implants were assessed after a 15-year follow-up. The clinical parameters were low and comparable between the implant types (OsseoTite XP Certain, OsseoTite XP Certain Prevail, NanoTite XP Certain, NanoTite XP Certain Prevail, PalmBeach Gardens, FL, USA) over time. The implants that incorporated a platform switch showed significantly less bone loss than the implants without a platform switch (-0.37 mm, 95% CI -0.69 to -0.05 mm, = 0.024 and β = -0.47, 95% CI -0.80 to -0.14, = 0.006). The implants with splinted restorations experienced more bone loss over time compared to the implants with solitary restorations (0.39 mm, 95% CI 0.15-0.63, = 0.002). Patient satisfaction was high after 15 years. All the tested dental implants with 8.5 mm length provide satisfactory 15-year results with regard to the clinical and radiographical parameters as well as patient satisfaction. The platform-matched implants were associated with more bone loss compared to the platform-switched implants, and the implants with splinted crowns portrayed more bone loss than the solitary implant crowns.

摘要

种植体特性(如种植体长、平台转换和牙冠联冠)对种植体周围健康的长期影响需要更多研究。因此,本研究旨在评估一组患者的种植体周围长期健康状况和患者满意度。这些患者来自两项前瞻性随机对照试验,在15年的时间里接受了8.5毫米长的牙科种植体,其上颌结构为联冠或单冠,且有或没有平台转换。122名患者接受了一颗或两颗8.5毫米长的牙科种植体(共223颗种植体),有或没有平台转换,在后牙区采用单冠修复(n = 89)或联冠修复(n = 134)。在修复体植入后的1个月、1年、5年和15年,前瞻性记录临床和影像学参数以及患者满意度。通过一份使用5分制和视觉模拟量表(0 - 10)的自填问卷记录患者满意度。在15年随访后,对81名患者的154颗种植体进行了评估。随着时间推移,各种植体类型(美国佛罗里达州棕榈滩花园市的OsseoTite XP Certain、OsseoTite XP Certain Prevail、NanoTite XP Certain、NanoTite XP Certain Prevail)的临床参数较低且相近。采用平台转换的种植体显示出的骨吸收明显少于未采用平台转换的种植体(-0.37毫米,95%可信区间为-0.69至-0.05毫米,P = 0.024;β = -0.47,95%可信区间为-0.80至-0.14,P = 0.006)。与单冠修复的种植体相比,联冠修复的种植体随时间出现更多的骨吸收(0.39毫米,95%可信区间为0.15 - 0.63,P = 0.002)。15年后患者满意度较高。所有测试的8.5毫米长牙科种植体在临床和影像学参数以及患者满意度方面均提供了令人满意的15年结果。与采用平台转换的种植体相比,平台匹配的种植体骨吸收更多,联冠种植体比单冠种植体的骨吸收更多。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b56c/11396484/5904ac5892b9/jcm-13-05162-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验