Suppr超能文献

基于新型扫频光学相干断层扫描技术的高度近视眼虹膜形态学特征

Morphologic features of iris in highly myopic eyes based on a novel swept-source optical coherence tomography.

作者信息

Kang Ching, Meng Jiaqi, Wang Lan, Chen Chao, Chen Yuxi, He Wenwen, Zhang Keke, Lu Yi, Fang Yanwen, Zhu Xiangjia

机构信息

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.

NHC Key Laboratory of Myopia and Related Eye Diseases, Shanghai, 200031, China.

出版信息

Eye (Lond). 2024 Dec;38(18):3443-3449. doi: 10.1038/s41433-024-03321-9. Epub 2024 Sep 15.

Abstract

BACKGROUND

To investigate the morphologic features of iris in the highly myopic (HM) eyes using a novel swept-source optical coherence tomography (SS-OCT).

METHODS

In this retrospective case-control study, 100 eyes of 100 patients scheduled to have cataract surgery were included, categorized into the control (22 mm< AL < 24.5 mm) and HM (AL ≥ 26 mm) groups. Iris volume (IV), area of anterior iris surface (IS), area of posterior IS, and average iris thickness (IT), as well as anterior chamber volume (ACV) and trabecular-iris space at 500 µm (TISA 500) were evaluated using SS-OCT. The associated factors with morphologic features of iris were also investigated.

RESULTS

The HM group showed significantly larger IV and area of anterior and posterior IS than the control group (all P < 0.001), while no difference was identified in IT between the groups. Similar trend in IV was seen in the superior and nasal segments, and area of anterior and posterior IS showed similar trends in all segments except the temporal segment. The IV, area of anterior and posterior IS were all positively correlated with AL (all P < 0.001). Multivariate linear regression revealed that a larger IV was associated with greater ACV. Both larger areas of anterior IS and posterior IS were associated with male, longer AL, greater ACV, and smaller TISA 500.

CONCLUSIONS

The HM eyes showed larger IV and area of IS than the control eyes, indicating a coronal expansion of the iris with AL. Iris morphology correlated with anterior chamber angle configuration.

摘要

背景

使用新型扫频光学相干断层扫描(SS-OCT)研究高度近视(HM)眼中虹膜的形态特征。

方法

在这项回顾性病例对照研究中,纳入了100例计划进行白内障手术患者的100只眼,分为对照组(22 mm < 眼轴长度[AL] < 24.5 mm)和HM组(AL ≥ 26 mm)。使用SS-OCT评估虹膜体积(IV)、虹膜前表面面积(IS)、虹膜后表面面积、平均虹膜厚度(IT),以及前房体积(ACV)和500 µm处的小梁-虹膜间隙(TISA 500)。还研究了与虹膜形态特征相关的因素。

结果

HM组的IV以及虹膜前、后表面面积均显著大于对照组(均P < 0.001),而两组间IT无差异。在上方和鼻侧节段观察到IV有类似趋势,除颞侧节段外,虹膜前、后表面面积在所有节段均呈现类似趋势。IV、虹膜前、后表面面积均与AL呈正相关(均P < 0.001)。多变量线性回归显示,较大的IV与较大的ACV相关。虹膜前、后表面面积较大均与男性、较长的AL、较大的ACV和较小的TISA 500相关。

结论

HM眼的IV和IS面积大于对照眼,表明虹膜随AL呈冠状扩张。虹膜形态与前房角结构相关。

相似文献

4
Peripheral iridotomy for pigmentary glaucoma.色素性青光眼的周边虹膜切开术
Cochrane Database Syst Rev. 2016 Feb 12;2(2):CD005655. doi: 10.1002/14651858.CD005655.pub2.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验