Department of Ophthalmology, The First Affiliated Hospital of China Medical University, Shenyang, China.
Transl Vis Sci Technol. 2024 Sep 3;13(9):24. doi: 10.1167/tvst.13.9.24.
This study presents a novel, three-dimensional method for measuring the tilt angle of the tilted optic disc (TOD) using spectral-domain optical coherence tomography (SD-OCT) and investigates the correlation between ocular-related parameters and TOD.
We included the right eyes of 243 healthy young individuals, categorized by axial length. We measured the ovality index (OI) and dihedral angle (DA) using SD-OCT infrared ray fundus photographs and high-resolution cross-sectional images of the optic disc, respectively. The relationships between OI, DA, and ocular-related parameters were analyzed.
Eyes in the longer axial length group exhibited a lower OI and a higher DA, along with thinner nasal and inferonasal circumpapillary retinal nerve fiber layer (cpRNFL) and thicker temporal and superotemporal cpRNFL. There was a significant relationship between DA and cpRNFL thickness. The new method utilizing DA to measure the tilt angle of TOD demonstrated high repeatability.
We propose a novel, three-dimensional, and quantitative method for evaluating the tilt degree of TOD. A higher degree of myopia indicated a greater tilt angle of the TOD, and a greater TOD suggested additional changes in cpRNFL thickness. These findings should be considered when interpreting increased susceptibility and early assessment of glaucoma in myopia.
DA could serve as a superior indicator for describing TOD morphology during eyeball elongation and evaluating its impact on related parameters of the optic disc and peripapillary structures in the myopic population.
本研究提出了一种新颖的三维方法,利用频域光相干断层扫描(SD-OCT)测量倾斜视盘(TOD)的倾斜角度,并探讨了眼部相关参数与 TOD 之间的相关性。
我们纳入了 243 名健康的年轻个体的右眼,按眼轴长度进行分类。我们使用 SD-OCT 红外眼底照片测量了椭圆度指数(OI),使用高分辨率的视盘横截面图像测量了二面角(DA)。分析了 OI、DA 与眼部相关参数之间的关系。
眼轴较长组的眼睛表现出较低的 OI 和较高的 DA,同时伴有更薄的鼻侧和鼻下方、颞侧和上方的环周视网膜神经纤维层(cpRNFL),以及更厚的颞侧和上方的 cpRNFL。DA 与 cpRNFL 厚度之间存在显著关系。利用 DA 测量 TOD 倾斜角度的新方法具有较高的可重复性。
我们提出了一种评估 TOD 倾斜程度的新颖的三维定量方法。高度近视表明 TOD 的倾斜角度更大,而更大的 TOD 则表明 cpRNFL 厚度有额外的变化。在解释近视患者青光眼易感性增加和早期评估时,应考虑这些发现。