Iliescu Ștefan, Voroneanu Luminita, Covic Alexandra Maria, Scripcariu Dragos Viorel, Stătescu Cristian, Covic Adrian C
Institute of Cardiovascular Diseases "Prof. Dr. George I.M. Georgescu", 700503 Iasi, Romania.
Faculty of Medicine, University of Medicine and Pharmacy "Grigore T. Popa", 700115 Iasi, Romania.
J Clin Med. 2024 Sep 19;13(18):5543. doi: 10.3390/jcm13185543.
The use of cardiac implantable electronic devices (CIEDs) has increased considerably, becoming a cornerstone of management for patients with brady- or tachyarrhythmia or for the prevention of sudden cardiac death. On the other hand, tricuspid regurgitation (TR) associated with CIEDs is progressively accepted as a serious clinical issue; the prognostic impact of TR is profound, as it is independently associated with increased mortality and a higher risk of heart failure hospitalization. Additionally, the management of established CIED-related TR continues to be challenging, with limited options for intervention once significant TR has developed. The balance between the lifesaving benefits of CIEDs and the risk of TR underlines the necessity for cautious patient selection and innovative approaches to device implantation and management. This review highlights the clinical importance, underlying mechanisms and challenges associated with lead-related tricuspid regurgitation in patients with CIEDs.
心脏植入式电子设备(CIEDs)的使用已大幅增加,成为缓慢性或快速性心律失常患者管理或预防心源性猝死的基石。另一方面,与CIEDs相关的三尖瓣反流(TR)逐渐被视为一个严重的临床问题;TR的预后影响深远,因为它与死亡率增加和心力衰竭住院风险较高独立相关。此外,已确立的与CIED相关的TR的管理仍然具有挑战性,一旦出现严重TR,干预选择有限。CIEDs的救命益处与TR风险之间的平衡凸显了谨慎选择患者以及采用创新的设备植入和管理方法的必要性。本综述强调了与CIEDs患者中与导线相关的三尖瓣反流相关的临床重要性、潜在机制和挑战。