Suppr超能文献

下颌前伸式咬合板对严重强度下直至力竭跑步的运动学影响。

Kinematical Effects of a Mandibular Advancement Occlusal Splint on Running until Exhaustion at Severe Intensity.

机构信息

Centre of Research, Education, Innovation and Intervention in Sport, CIFI2D, and Porto Biomechanics Laboratory, LABIOMEP-UP, Faculty of Sport, University of Porto, 4200-450 Porto, Portugal.

Faculty of Dental Medicine, University of Porto, 4200-393 Porto, Portugal.

出版信息

Sensors (Basel). 2024 Sep 18;24(18):6032. doi: 10.3390/s24186032.

Abstract

The effects of occlusal splints on sport performance have already been studied, although their biomechanical impacts are often overlooked. We investigated the kinematical changes during running until exhaustion at severe intensity while wearing a mandibular advancement occlusal splint. Twelve trained runners completed (i) an incremental protocol on a track to determine their velocity corresponding to maximal oxygen uptake and (ii) two trials of square wave transition exercises at their velocity corresponding to maximal oxygen until exhaustion, wearing two occlusal splints (without and with mandibular advancement). Running kinematics were compared within laps performed during the square wave transition exercises and between splint conditions. The mandibular advancement occlusal splint increased the running distance covered (~1663 ± 402 vs. 1540 ± 397 m, = 0.03), along with a noticeable lap effect in decreasing stride frequency ( = 0.04) and increasing stride length ( = 0.03) and duty factor ( 0.001). No spatiotemporal differences were observed between splints, except for improved balance foot contact times in the mandibular advancement condition. An increased knee flexion angle at initial contact ( = 0.017) was noted along laps in the non-advancement condition, despite the fact that no differences between splints were found. Running patterns mainly shifted within laps rather than between conditions, indicating that a mandibular advancement occlusal splint had a trivial kinematical effect.

摘要

虽然已经研究了咬合夹板对运动表现的影响,但它们的生物力学影响往往被忽视。我们研究了在剧烈强度下穿着下颌前伸咬合夹板跑步直至力竭时的运动学变化。十二名经过训练的跑步者完成了以下两项测试:(i)在跑道上进行递增式测试,以确定与最大摄氧量相对应的速度;(ii)在与最大摄氧量相对应的速度下进行两次方波过渡练习,直到力竭,同时佩戴两种咬合夹板(无下颌前伸和有下颌前伸)。在方波过渡练习期间,对每个跑步圈的跑步运动学进行了比较,并比较了两种夹板条件下的跑步运动学。下颌前伸咬合夹板增加了跑步距离(~1663 ± 402 与 1540 ± 397 m, = 0.03),同时,步频明显下降( = 0.04),步长增加( = 0.03),步幅利用率增加( 0.001)。除了在有下颌前伸的条件下改善平衡脚接触时间外,在两种夹板之间没有观察到时空差异。尽管在非前伸条件下在每个跑步圈中都观察到初始接触时膝关节弯曲角度增加( = 0.017),但在两种夹板之间未发现差异。跑步模式主要在每个跑步圈中发生变化,而不是在两种夹板条件之间发生变化,这表明下颌前伸咬合夹板的运动学影响很小。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2957/11435913/6afcea402523/sensors-24-06032-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验