OBJECTIVE

Reproducibility is key for diagnostic tests involving subjective evaluation by experts. Our aim was to systematically review the reproducibility of visual analysis in clinical electroencephalogram (EEG). In this paper, we give data on the scope of EEG features found, and detailed reproducibility data for the most studied feature.

METHODS

We searched four databases for articles reporting reproducibility in clinical EEG, until June 2023. Two raters screened 24 553 citations, and then 2736 full texts. Quality was assessed according to the GRRAS guidelines.

RESULTS

We found 275 studies (268 interrater and 20 intrarater), addressing 606 different EEG features. Only 38 EEG features had been studied in >2 studies. Most studies had <50 patients and EEGs. The most often addressed feature was seizure detection (62 papers). Interrater reproducibility of seizure detection was substantial-to-almost-perfect with experienced raters and raw EEG (kappa .62-.88). With experienced raters and transformed EEG, reproducibility was substantial (kappa .63-.70). Inexperienced raters had lower reproducibility. Seizure lateralization reproducibility was moderate to substantial (kappa .58-.77) but lower than for seizure detection.

SIGNIFICANCE

Most EEG reproducibility studies are done only once. Intrarater studies are rare. The reproducibility of visual EEG analysis is variable. Interrater reproducibility for seizure detection is substantial-to-perfect with experienced raters and raw EEG, less with inexperienced raters or transformed EEG. The results of visual EEG analysis vary within the same rater, and between raters. There is a need for larger collaborative studies, using improved methodology, as well as more intrarater studies of EEG interpretation.

摘要

目的

对于涉及专家主观评估的诊断测试而言,可重复性是关键。我们的目的是系统评价临床脑电图(EEG)视觉分析的可重复性。在本文中,我们给出了所发现的EEG特征范围的数据,以及对研究最多的特征的详细可重复性数据。

方法

我们检索了四个数据库,以查找截至2023年6月报告临床EEG可重复性的文章。两名评估者筛选了24553条引文,然后筛选了2736篇全文。根据GRRAS指南评估质量。

结果

我们发现了275项研究(268项评估者间和20项评估者内),涉及606种不同的EEG特征。只有38种EEG特征在超过2项研究中被研究过。大多数研究的患者和EEG数量少于50。研究最多的特征是癫痫发作检测(62篇论文)。对于经验丰富的评估者和原始EEG,癫痫发作检测的评估者间可重复性为高度到几乎完美(kappa值为0.62 - 0.88)。对于经验丰富的评估者和转换后的EEG,可重复性为高度(kappa值为0.63 - 0.70)。经验不足的评估者可重复性较低。癫痫发作定位的可重复性为中度到高度(kappa值为0.58 - 0.77),但低于癫痫发作检测。

意义

大多数EEG可重复性研究仅进行了一次。评估者内研究很少。EEG视觉分析的可重复性是可变的。对于癫痫发作检测,经验丰富的评估者和原始EEG的评估者间可重复性为高度到完美,经验不足的评估者或转换后的EEG的可重复性较低。EEG视觉分析的结果在同一评估者内以及评估者之间存在差异。需要采用改进的方法进行更大规模的合作研究,以及更多关于EEG解读的评估者内研究。