Suppr超能文献

大鼠的套式遥测技术:一种用于跑步机运动期间心肺表型分析的新型非侵入性方法。

Jacketed telemetry in rats: a novel non-invasive method for cardiorespiratory phenotyping during treadmill exercise.

作者信息

Tanguy Stéphane, Cambier Agathe, Fontana-Pires Leandro, Flenet Timothé, Eynard Charles, Fontecave-Jalon Julie, Gumery Pierre-Yves, Boucher François

机构信息

Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, T IMC, 38000 Grenoble, France.

Etisense SAS, Lyon, France.

出版信息

Lab Anim. 2025 Apr;59(2):215-225. doi: 10.1177/00236772241259857. Epub 2024 Sep 30.

Abstract

The development of alternative methods for monitoring cardiorespiratory function without restraint or surgical implantation is attracting growing interest for both ethical and scientific reasons. For this purpose, a new non-invasive jacketed telemetry tool consisting in a radio device maintained in a jacket worn by the animal was previously developed to improve cardiorespiratory monitoring. It allows simultaneous monitoring of cardiac activity by surface electrocardiagram, respiratory function by respiratory inductive plethysmography, and locomotor activity by accelerometry. However, this tool has only been validated under conditions of low/intermediate activity levels or in anesthetized animals. This study aimed to evaluate the feasibility of using this system in the challenging conditions of an exertion protocol. Male Wistar rats ( = 10, 8-9 weeks old) were subjected to an incremental treadmill exercise protocol including speed levels from 5 to 40 cm s separated by 30-s breaks. Heart rate (HR) and minute ventilation (assessed by minute volume; MV) were continuously monitored. At the end of each running level and during the 30-s breaks, HR and MV showed a significant increase compared to resting values. They returned to the baseline within 60 min of post-exercise recovery. Overall, our results demonstrated (i) the ability of the animal to run while wearing the device and (ii) the ability of the device to reliably monitor cardiorespiratory adaptation to treadmill exercise despite significant mechanical disturbances. In conclusion, this study highlights the possibility of non-invasively monitoring cardiorespiratory functional variables that were previously unattainable under conditions of high activity in freely moving animals.

摘要

出于伦理和科学原因,开发无需束缚或手术植入即可监测心肺功能的替代方法正引起越来越多的关注。为此,先前开发了一种新型无创夹套式遥测工具,该工具由一个无线电设备组成,该设备放置在动物佩戴的夹套中,以改善心肺监测。它可以通过体表心电图同时监测心脏活动,通过呼吸感应体积描记法监测呼吸功能,并通过加速度计监测运动活动。然而,该工具仅在低/中等活动水平条件下或麻醉动物中得到验证。本研究旨在评估在运动方案的挑战性条件下使用该系统的可行性。雄性Wistar大鼠(n = 10,8 - 9周龄)接受递增式跑步机运动方案,速度水平从5到40 cm/s,间隔30秒休息。持续监测心率(HR)和分钟通气量(通过分钟容积评估;MV)。在每个跑步水平结束时以及30秒休息期间,HR和MV与静息值相比均显著增加。它们在运动后恢复的60分钟内恢复到基线水平。总体而言,我们的结果表明:(i)动物佩戴该设备时能够跑步;(ii)尽管存在明显的机械干扰,该设备仍能够可靠地监测心肺对跑步机运动的适应性。总之,本研究突出了在自由活动动物的高活动条件下非侵入性监测以前无法实现的心肺功能变量的可能性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验