使用前房气泡和皮质液释放技术预防膨胀性白内障中的阿根廷国旗征。

Prevention of Argentinian flag sign in intumescent cataracts using anterior chamber air bubble and cortical fluid release techniques.

机构信息

State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanics and Civil Engineering, China University of Mining and Technology, Xuzhou, 221116, Jiangsu, China.

The Affiliated Xuzhou Municipal Hospital of Xuzhou Medical University, Xu Zhou, China.

出版信息

BMC Ophthalmol. 2024 Oct 2;24(1):430. doi: 10.1186/s12886-024-03679-0.

Abstract

BACKGROUND

To investigate the efficiency of a new method for the prevention of argentinian flag sign during the process of continuous, circular, and centered anterior capsulotomy (CCC) on the anterior capsule in cortically liquefied intumescent cataracts. This study was registered in an appropriate registry and the registration number of registration was xyy11[2022]-XJSFX-087; The date of of registration was 2022-04-29.

METHODS

Preoperative examinations including slit-lamp examination, ocular A-scan ultrasonography, and Ultrasound Biomicroscopy (UBM) UBM were conducted on 61 patients with intumescent cataracts. Cases with cortically liquefied intumescent cataracts were selected and after staining with indocyanine green, the anterior chamber air bubble technique was used to compress the anterior capsule, and liquefied cortex was aspirated using a puncture needle. Corrected Distance Visual Acuity (CDVA) and intraocular pressure were recorded on postoperative days 1, 1 week, 1 month, and 6 months. Intraoperative and postoperative complications were documented and analyzed.

RESULTS

Fifty eyes were identified as having cortically liquefied intumescent cataracts. No cases of the Argentinian flag sign occurred, and standard capsulorrhexis was achieved, facilitating smooth phacoemulsification. All patients achieved satisfactory outcomes at follow-ups of 1 day, 1 week, 1 month, and 6 months postoperatively. Mild corneal edema was observed in three cases on the first postoperative day, with no other complications noted.

CONCLUSIONS

The anterior chamber air bubble technique combined with cortical fluid release technique can prevent the occurrence of the Argentinian flag sign in cortically liquefied intumescent cataracts, this method is simple, convenient and economic for the clinical promotion.

摘要

背景

研究一种新方法在皮质液化膨胀性白内障前囊环形连续中心截囊术中预防阿根廷国旗征的效果。本研究在适当的注册机构进行注册,注册号为 xyy11[2022]-XJSFX-087;注册日期为 2022 年 4 月 29 日。

方法

对 61 例膨胀性白内障患者进行术前检查,包括裂隙灯检查、眼部 A 超检查和超声生物显微镜(UBM)UBM。选择皮质液化膨胀性白内障病例,采用吲哚菁绿染色后,采用前房气泡技术压迫前囊,采用穿刺针抽吸液化皮质。记录术后第 1、1 周、1 个月和 6 个月的矫正距离视力(CDVA)和眼压。记录并分析术中及术后并发症。

结果

发现 50 只眼为皮质液化膨胀性白内障。无阿根廷国旗征发生,标准截囊成功,便于顺利进行超声乳化。所有患者在术后 1 天、1 周、1 个月和 6 个月的随访中均获得满意的结果。术后第 1 天有 3 例出现轻度角膜水肿,无其他并发症。

结论

前房气泡技术联合皮质液释放技术可预防皮质液化膨胀性白内障中阿根廷国旗征的发生,该方法简便、经济,有利于临床推广。