Suppr超能文献

小鼠对使用滴注法进行异氟烷诱导的厌恶反应。

Mouse aversion to induction with isoflurane using the drop method.

作者信息

Bodnar Maya J, Makowska I Joanna, Boyd Courtney T, Schuppli Catherine A, Weary Daniel M

机构信息

UBC Animal Welfare Program, Faculty of Land and Food Systems, The University of British Columbia, Vancouver, Canada.

出版信息

Lab Anim. 2025 Apr;59(2):169-177. doi: 10.1177/00236772241262119. Epub 2024 Oct 4.

Abstract

Isoflurane anesthesia prior to carbon dioxide euthanasia is recognized as a refinement by many guidelines. Facilities lacking access to a vaporizer can use the "drop" method, whereby liquid anesthetic is introduced into an induction chamber. Knowing the least aversive concentration of isoflurane is critical. Previous work has demonstrated that isoflurane administered with the drop method at a concentration of 5% is aversive to mice. Other work has shown that lower concentrations (1.7% to 3.7%) of isoflurane can be used to anesthetize mice with the drop method, but aversion to these concentrations has not been tested. We assessed aversion to these lower isoflurane concentrations administered with the drop method, using a conditioned place aversion (CPA) paradigm. Female C57BL/6J (OT-1) mice ( = 28) were randomly allocated to one of three isoflurane concentrations: 1.7%, 2.7%, and 3.7%. Mice were acclimated to a light-dark apparatus. Prior to and following dark (+ isoflurane) and light chamber conditioning sessions, mice underwent an initial and final preference assessment; the change in the duration spent within the dark chamber between the initial and final preference tests was used to calculate a CPA score. Aversion increased with increasing isoflurane concentration: from 1.7% to 2.7% to 3.7% isoflurane, mean ± SE CPA score decreased from 19.6 ± 20.1 s to -25.6 ± 23.2 s, to -116.9 ± 30.6 s ( = 15.4,  < 0.001). Our results suggest that, when using the drop method to administer isoflurane, concentrations between 1.7% and 2.7% can be used to minimize female mouse aversion to induction.

摘要

许多指南都认可在二氧化碳安乐死之前使用异氟烷麻醉作为一种优化方法。没有蒸发器的设施可以使用“滴入”法,即将液体麻醉剂引入诱导室。了解异氟烷的最低厌恶浓度至关重要。先前的研究表明,以5%的浓度通过滴入法给予异氟烷会引起小鼠的厌恶。其他研究表明,较低浓度(1.7%至3.7%)的异氟烷可用于通过滴入法麻醉小鼠,但尚未测试对这些浓度的厌恶情况。我们使用条件性位置厌恶(CPA)范式评估了通过滴入法给予这些较低异氟烷浓度时的厌恶情况。将28只雌性C57BL/6J(OT-1)小鼠随机分配到三种异氟烷浓度之一:1.7%、2.7%和3.7%。小鼠适应了明暗装置。在黑暗(+异氟烷)和明亮室条件训练之前和之后,小鼠进行了初始和最终偏好评估;初始和最终偏好测试之间在黑暗室中停留时间的变化用于计算CPA分数。厌恶程度随异氟烷浓度的增加而增加:从1.7%异氟烷到2.7%异氟烷再到3.7%异氟烷,平均±标准误的CPA分数从19.6±20.1秒降至-25.6±23.2秒,再降至-116.9±30.6秒(F = 15.4,P < 0.001)。我们的结果表明,当使用滴入法给予异氟烷时,1.7%至2.7%的浓度可用于使雌性小鼠对诱导的厌恶最小化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d427/12064859/d3736c731d4e/10.1177_00236772241262119-fig1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验