Visual and Refractive Outcomes after Phacoemulsification Cataract Surgery in Nanophthalmic Eyes.

作者信息

Lai Tracy H T, Tse Jeffrey Y T, Chan Jacqueline W T, Li Kenneth K W

机构信息

Department of Ophthalmology, Tseung Kwan O Hospital, 2 Po Ning Lane, Tseung Kwan O, Hong Kong.

Department of Ophthalmology, United Christian Hospital, 130 Hip Wo Street, Kwun Tong, Hong Kong.

出版信息

J Clin Med. 2024 Sep 30;13(19):5852. doi: 10.3390/jcm13195852.

Abstract

: The aim of this study was to report the visual and refractive outcomes of nanophthalmic eyes undergoing phacoemulsification at a tertiary cataract center. This is a prospective consecutive case series. Patients with an axial length of ≤20.5 mm who underwent phacoemulsification at a tertiary cataract center in Hong Kong were included. Eyes undergoing extracapsular cataract extraction or with a previous history of intraocular surgery including trabeculectomy were excluded. The outcome measures were the corrected distance visual acuity (CDVA) and refractive status at four months post-operation. Different intraocular lens formulas were used to compare the refractive outcomes. Out of 22,847 cataract surgeries performed from May 2011 to March 2020, 14 eyes (0.06%) of 10 patients had axial lengths of ≤20.5 mm and underwent phacoemulsification. The mean axial length was 20.13 ± 0.44 mm. Out of these fourteen eyes, three (21%) had postoperative myopic shift with spherical equivalent refraction of more than or equal to 1D compared to the original target. Eleven eyes (79%) had postoperative refraction within 0.5D compared to the original target. Nine out of fourteen eyes (64%) had improvements in postoperative vision. There were no intraoperative complications. When comparing the Hoffer Q, Holladay 1, Holladay 2, Haigis and Hill-RBF 2.0 formulas, there was no significant difference in the absolute errors between the five formulas ( = 0.072). There was no significant difference in the mean absolute errors between the Hoffer Q, Holladay 1, Holladay 2, Haigis and Hill-RBF 2.0 formulas. Myopic shift was not uncommon, and more studies on intraocular lens (IOL) power calculation for short eyes are warranted.

摘要

本研究的目的是报告在一家三级白内障中心接受超声乳化手术的小眼球的视力和屈光结果。这是一个前瞻性连续病例系列。纳入在香港一家三级白内障中心接受超声乳化手术且眼轴长度≤20.5 mm的患者。排除接受囊外白内障摘除术的眼或有包括小梁切除术在内的既往眼内手术史的眼。结局指标为术后四个月的矫正远视力(CDVA)和屈光状态。使用不同的人工晶状体公式比较屈光结果。在2011年5月至2020年3月进行的22847例白内障手术中,10例患者的14只眼(0.06%)眼轴长度≤20.5 mm并接受了超声乳化手术。平均眼轴长度为20.13±0.44 mm。在这14只眼中,3只(21%)术后出现近视偏移,等效球镜度比原始目标值增加或等于1D。11只眼(79%)术后屈光与原始目标值相差在0.5D以内。14只眼中有9只(64%)术后视力有改善。术中无并发症。比较霍夫Q、霍拉迪1、霍拉迪2、海吉斯和希尔-RBF 2.0公式时,五个公式之间的绝对误差无显著差异( = 0.072)。霍夫Q、霍拉迪1、霍拉迪2、海吉斯和希尔-RBF 2.0公式之间的平均绝对误差无显著差异。近视偏移并不少见,因此有必要对短眼人工晶状体(IOL)屈光度计算进行更多研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ad24/11477411/db538bab30c0/jcm-13-05852-g001.jpg