Suppr超能文献

用于评估频闪检查时游离缘黏膜波动力学的评分量表:临床验证研究及结果分析。

Scale for the assessment of mucosal wave dynamics of the free edges during stroboscopic examination: clinical validation study and analysis of results.

机构信息

Department of Otorhinolaryngology and Head and Neck Surgery, Hospital Vithas Arturo Soria Madrid, Calle de Arturo Soria 105, Madrid, 28043, Spain.

Department of Medicine, Faculty of Biomedical and Health Sciences, Faculty of Medicine and Surgery, Chair of Human Anatomy and Embryology, European University of Madrid, Madrid, Spain.

出版信息

Eur Arch Otorhinolaryngol. 2024 Dec;281(12):6565-6577. doi: 10.1007/s00405-024-08975-5. Epub 2024 Oct 16.

Abstract

INTRODUCTION

Identifying the mucosal wave (MW) is essential when studying the voice; however, its characterization and perceived measurement during laryngeal stroboscopy (LS) are not well defined or standardized because of the subjectivity of its interpretation. This article proposed and validated a scale that characterized and approximated MW measurement during LS, applied it to participants divided into a healthy group and groups with free edge conditions, and identified differences between them.

METHODS

This is a descriptive and clinical validation study of the "VASQ (Vertical axis, Anteroposterior axis, Symmetry and Quantity) mucosal wave score" scale based on stroboscopy images of 137 adult men and women divided into a control group and functional and organic pathology groups. The images were analyzed by three evaluators according to an established protocol. Measurements dictating the reproducibility and validity criteria as well as the MW score in each group were obtained.

RESULTS

The reliability of the scale was α = 0.90, internal consistency success rate was 91%, intra-observer reliability was 0.83, inter-observer reliability was 0.83, content validity coefficient was 0.92, and factor loading was 0.37-0.53. The MW total score values between 5 and 6 were established as a reference for normality (P < 0.05). Organic pathology showed lower MW score values (P < 0.05), and functional pathology to a lesser extent (P > 0.05).

CONCLUSIONS

The proposed scale is a consistent, valid, and reliable tool. Its widespread application would favor commonly used terminology and facilitate quantitative comparisons in future studies.

摘要

简介

在研究嗓音时,识别黏膜波(MW)至关重要;然而,由于其解释的主观性,其特征描述和在频闪喉镜(LS)中感知的测量尚未得到很好的定义或标准化。本文提出并验证了一种用于 LS 期间特征描述和近似 MW 测量的量表,并将其应用于分为健康组和自由缘条件组的参与者中,以识别它们之间的差异。

方法

这是一项基于 137 名成年男女的频闪镜图像的描述性和临床验证研究,这些参与者分为对照组和功能及器质性病理组。根据既定方案,三位评估者对图像进行分析。获得了决定可重复性和有效性标准的测量值,以及每个组的 MW 评分。

结果

该量表的可靠性为 α = 0.90,内部一致性成功率为 91%,观察者内可靠性为 0.83,观察者间可靠性为 0.83,内容有效性系数为 0.92,因子负荷为 0.37-0.53。MW 总分值在 5 到 6 之间被确定为正常值的参考(P < 0.05)。器质性病理组的 MW 评分值较低(P < 0.05),而功能性病理组的程度较轻(P > 0.05)。

结论

所提出的量表是一种一致、有效和可靠的工具。其广泛应用将有利于常用术语的使用,并促进未来研究中的定量比较。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7c3d/11564220/5833ead03fcd/405_2024_8975_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验