模拟口腔条件下正畸弹性链的力衰减行为

Force Decay Behavior of Orthodontic Elastomeric Chains in Simulated Oral Conditions.

作者信息

Virdi Gurmeet K, Prashar Anil, Kaur Gurpreet, Jabbal Ravudai S, Aggarwal Pancham, Budh Sahil, Singh Disha

机构信息

Orthodontics and Dentofacial Orthopedics, Desh Bhagat Dental College and Hospital, Mandi Gobindgarh, IND.

Prosthodontics, Genesis Institute of Dental Sciences and Research, Ferozepur, IND.

出版信息

Cureus. 2024 Sep 22;16(9):e69908. doi: 10.7759/cureus.69908. eCollection 2024 Sep.

Abstract

Background Elastomeric chains are widely used for incisor retraction and space closure. However, the force they exert diminishes over time, and this makes it difficult to determine the actual force transmitted to the dentition. The force decay may also be affected by exposure to saliva, foods, beverages, and prophylactic agents. Objective To assess the force degradation of four commercially available orthodontic elastomeric chains (AlastiK, 3M; Generation II Power Chain, Ormco; Elastic Chain, Morelli; and Plastic Chain, American Orthodontics) over 28 days in simulated oral conditions using tooth movement and a prophylactic fluoride rinse regimen. Method A total of 80 chain samples, with 20 samples of each chain type having four loops each, were stretched to 25 mm on custom-fabricated acrylic resin jigs with provision for a space closure mechanism. The samples were divided equally into two groups: a control group, in which ten samples of each chain type were maintained in artificial saliva at 37°C, and a test group, in which ten samples of each chain type were maintained in artificial saliva at 37°C and additionally subjected to simulated tooth movement with jig closure of 0.25 mm/week and a twice-daily regimen of prophylactic fluoride rinse. Force decay was measured using a digital force gauge at the time of engagement on the jigs, at one hour, four hours, and at one, seven, 14, 21, and 28 days. Percentage force decay was calculated, and the results were subjected to one-way analysis of variance (ANOVA), post-hoc Tukey, post-hoc Bonferroni, and 't' test. Results Maximum force degradation was observed at one day for all four chain materials in both groups, followed by a steady force loss over 28 days, the difference being significant for all materials at various time intervals (p<0.05). No significant difference was observed between any material at any given time in the control group (p>0.05); however, significant differences were observed in the test group. Under simulated oral conditions, force decay was maximum for the Plastic Chain, American Orthodontics (67.9 ± 6.24%), and minimum for the Generation II Power Chain, Ormco (51.9 ± 9.78%) at the end of the test period. Conclusion Plastic Chain, American Orthodontics, and AlastiK, 3M chain, exhibited higher force decay when compared to Generation II Power Chain, Ormco, and Elastic Chain, Morelli. Simulated oral conditions significantly affected the force decay of elastomeric chains, and it may be desirable to change elastomeric chains at 14 days for optimum retraction force.

摘要

背景 弹性链广泛用于切牙后移和间隙关闭。然而,它们施加的力会随时间减弱,这使得难以确定传递到牙列的实际力。力的衰减也可能受到唾液、食物、饮料和预防剂的影响。目的 使用牙齿移动和预防性氟化物冲洗方案,评估四种市售正畸弹性链(AlastiK,3M公司;第二代动力链,奥美科公司;弹性链,莫雷利公司;塑料链,美国正畸公司)在模拟口腔条件下28天内的力降解情况。方法 总共80个链样本,每种链类型有20个样本,每个样本有四个环,在定制的丙烯酸树脂夹具上拉伸至25毫米,该夹具设有间隙关闭机制。样本平均分为两组:对照组,每种链类型的10个样本保存在37°C的人工唾液中;试验组,每种链类型的10个样本保存在37°C的人工唾液中,并额外进行模拟牙齿移动,夹具每周关闭0.25毫米,每天进行两次预防性氟化物冲洗。在夹具安装时、1小时、4小时以及1天、7天、14天、21天和28天时,使用数字测力计测量力的衰减。计算力衰减百分比,并对结果进行单因素方差分析(ANOVA)、事后Tukey检验、事后Bonferroni检验和“t”检验。结果 两组中所有四种链材料在第1天均观察到最大力降解,随后在28天内力持续损失,在不同时间间隔内所有材料的差异均具有统计学意义(p<0.05)。对照组中任何材料在任何给定时间均未观察到显著差异(p>0.05);然而,试验组中观察到显著差异。在模拟口腔条件下,试验期结束时,美国正畸公司的塑料链力衰减最大(67.9±6.24%),奥美科公司的第二代动力链力衰减最小(51.9±9.78%)。结论 与奥美科公司的第二代动力链和莫雷利公司的弹性链相比,美国正畸公司的塑料链和3M公司的AlastiK链表现出更高的力衰减。模拟口腔条件显著影响弹性链的力衰减,为获得最佳后移力,可能需要在14天时更换弹性链。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a44c/11495140/7e13639771ff/cureus-0016-00000069908-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验