Okulewicz Patrycja, Wojciuk Bartosz, Wojciechowska-Koszko Iwona, Domański Leszek, Gołembiewska Edyta
Department of Nephrology, Transplantology, and Internal Medicine, Pomeranian Medical University, Szczecin, Poland.
Department of Immunological Diagnostics, Pomeranian Medical University, Szczecin, Poland.
Front Med (Lausanne). 2024 Oct 9;11:1463391. doi: 10.3389/fmed.2024.1463391. eCollection 2024.
The number of relevant markers indicating local intraperitoneal inflammation in patients undergoing peritoneal dialysis (PD) is limited. Therefore, this study aimed to evaluate the compatibility of peritoneal effluent (PE) for proteomic analysis and assess its potential utility in immunoprofiling studies.
This pilot study included six PD patients from the Peritoneal Dialysis Center, Department of Nephrology, Transplantology, and Internal Medicine in Szczecin, Poland. All patients were clinically stable, with no signs of infections or malignancy at the time of study. PE samples were collected during routine surveillance visits at the Peritoneal Dialysis Center. Proteomic analysis of the samples was conducted using the Olink (Olink Proteomics AB, Uppsala, Sweden) Target 48 Cytokine panel.
PE samples were successfully analyzed, with 28 out of 45 proteins found within the limit of quantitation (LOQ) and 32 out of 45 proteins detected above the limit of detection (LOD). No significant interference from the matrix was observed in the assay. Biomarkers associated with low-grade inflammation showed varied levels, and the observed patterns were comparable across all patients.
This study suggests that utilizing a cytokine panel with relative quantification is a promising method for PE immunoprofiling.
用于指示接受腹膜透析(PD)患者局部腹膜内炎症的相关标志物数量有限。因此,本研究旨在评估腹膜透析液(PE)用于蛋白质组学分析的兼容性,并评估其在免疫谱分析研究中的潜在效用。
这项前瞻性研究纳入了来自波兰什切青市肾脏病、移植与内科系腹膜透析中心的6名PD患者。所有患者在研究时临床状况稳定,无感染或恶性肿瘤迹象。PE样本在腹膜透析中心的常规监测访视期间收集。使用Olink(瑞典乌普萨拉市Olink Proteomics AB公司)的Target 48细胞因子检测板对样本进行蛋白质组学分析。
PE样本成功进行了分析,45种蛋白质中有28种在定量限(LOQ)范围内被检测到,45种蛋白质中有32种在检测限(LOD)以上被检测到。在检测中未观察到来自基质的显著干扰。与低度炎症相关的生物标志物水平各异,在所有患者中观察到的模式具有可比性。
本研究表明,使用具有相对定量功能的细胞因子检测板是一种用于PE免疫谱分析的有前景的方法。