用于扩展焦深人工晶状体植入的地形图角膜曲率测量法与生物测量角膜曲率测量法之间的屈光精度。

The refractive accuracy between topographic keratometry and biometric keratometry for extended depth-of-focus intraocular lens implantation.

作者信息

Lee Chia-Yi, Yang Shun-Fa, Chen Hung-Chi, Lian Ie-Bin, Huang Jing-Yang, Chang Chao-Kai

机构信息

Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan.

Nobel Eye Institute, Taipei, Taiwan.

出版信息

Int J Med Sci. 2024 Nov 4;21(15):2912-2918. doi: 10.7150/ijms.99907. eCollection 2024.

Abstract

To investigate the influence of different keratometry (K) measurements on the postoperative outcomes of cataract surgery with extended depth-of-focus (EDOF) intraocular lens (IOL) implantation. A retrospective cohort study was conducted, and patients who received cataract surgery and one type of EDOF IOL implantation were included. The patients were then categorized according to K measurements, and 70 and 30 eyes were included in the biometric-K and topographic-K groups, respectively. The primary outcomes were postoperative uncorrected distance visual acuity (UDVA), spherical equivalent (SE) and cylinder power. A generalized linear model was applied to compare the adjusted odds ratios (aORs) and 95% confidence intervals (CIs) of the outcomes between groups. One month after surgery, the UDVA was 0.15 and 0.07 in the biometric-K group and topographic-K group, respectively. Furthermore, the final SEs were -0.42 D and -0.13 D in the biometric-K group and topographic-K group, respectively, and the final cylinder powers were -0.35 D and -0.13 D in the biometric-K group and topographic-K group, respectively. According to the multivariate analysis, the topographic-K group presented a significantly better UDVA (P = 0.044) and significantly lower cylinder power (P = 0.031) than the biometric-K group. Angle kappa was significantly correlated with high postoperative astigmatism in the topographic-K group (P = 0.033), whereas angle kappa, steep K, and corneal cylinder powers were significantly correlated with high postoperative astigmatism in the biometric-K group (all P < 0.05). Topography-based K measurements yielded better refractive outcomes than biometric-based K measurements did.

摘要

为研究不同角膜曲率(K)测量值对采用扩展景深(EDOF)人工晶状体(IOL)植入的白内障手术术后效果的影响。进行了一项回顾性队列研究,纳入接受白内障手术并植入一种EDOF IOL的患者。然后根据K测量值对患者进行分类,生物测量K组和地形图K组分别纳入70只眼和30只眼。主要结局指标为术后裸眼远视力(UDVA)、等效球镜度(SE)和柱镜度数。应用广义线性模型比较各组间结局指标的调整比值比(aORs)和95%置信区间(CIs)。术后1个月,生物测量K组和地形图K组的UDVA分别为0.15和0.07。此外,生物测量K组和地形图K组的最终SE分别为-0.42 D和-0.13 D,最终柱镜度数分别为-0.35 D和-0.13 D。根据多因素分析,地形图K组的UDVA显著优于生物测量K组(P = 0.044),柱镜度数显著低于生物测量K组(P = 0.031)。在地形图K组中,角膜κ角与术后高散光显著相关(P = 0.033),而在生物测量K组中,角膜κ角、陡峭K值和角膜柱镜度数与术后高散光均显著相关(均P < 0.05)。基于地形图的K测量比基于生物测量的K测量产生更好的屈光效果。

相似文献

3
Comparison of different methods of correcting astigmatism in cataract surgery.白内障手术中不同散光矫正方法的比较
Clin Exp Optom. 2024 May;107(4):409-414. doi: 10.1080/08164622.2023.2239816. Epub 2023 Sep 12.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验