Suppr超能文献

即时超声(POCUS)引导下瞳孔评估参数与精神状态改变患者格拉斯哥昏迷量表的相关性——一项横断面研究

Correlation of Point of Care Ultrasound (POCUS) Guided Pupillary Assessment Parameter with Glasgow Coma Scale in Patients with Altered Mental Status- A Cross Sectional Study.

作者信息

Modi Priyanka, Bhoi Sanjeev

机构信息

Department of Emergency Medicine, All India Institute Of Medical Sciences (AIIMS) New Delhi IND.

出版信息

POCUS J. 2024 Nov 15;9(2):68-79. doi: 10.24908/pocus.v9i2.17449. eCollection 2024.

Abstract

Earlier studies have proved deteriorating Glasgow Coma Scale (GCS) as a marker of raised intracranial pressure (ICP). Low GCS is associated with abnormal pupillary parameters. Currently, many studies have proved that ultrasound provides a feasible and objective assessment of pupillary light reflex. However, literature is lacking to evaluate objective pupillary parameters to predict GCS of the patients by point of care ultrasound (POCUS). In this prospective, cross-sectional study, 200 patients were recruited in the emergency department. The inclusion criteria were patients older than 18 years with acute presentation of altered mental status. Exclusion criteria were patients who had partial globe rupture or dementia. The patients underwent a B-mode POCUS-guided evaluation at rest and after light stimulation. Statistical analysis of relationship between pupillary assessment parameters and GCS was performed using Spearman's Rank correlation coefficient, Kruskal-Wallis equality-of-populations rank test, and area under the receiver operating characteristic. The study consisted of 200 (42 female, 158 male) patients with mean (± standard deviation) of age and GCS of 43.56 ± 16.50 years and 5.54 ± 3.00, respectively. Majority of non-reactive pupils had a GCS Score of 3-8 (74 cases, 97.37%). The Pupillary diameter (PD) and PD variation showed statistically significant agreement with pupil reactivity to light stimulation and GCS, with Spearman's correlation coefficient ranging from 0.28 to 0.33 for PD, and -0.55 to -0.50 (p-value <0.05) for PD variation, respectively. PD variation rate (PDVR) is the percentage change in the magnitude of constriction of PD on light stimulation. PDVR of >19.68% had a sensitivity of 86.96% (95% CI: 82.04 - 91.88%) and specificity of 64.97% (95% CI: 58.00 - 71.94%) to detect GCS>8. PD variation and PDVR measured by POCUS has significant correlation with GCS >8. The study showed good sensitivity and low specificity of PDVR on light stimulation to detect GCS >8.

摘要

早期研究已证实格拉斯哥昏迷量表(GCS)恶化是颅内压(ICP)升高的一个指标。低GCS与异常瞳孔参数相关。目前,许多研究已证明超声可为瞳孔对光反射提供可行且客观的评估。然而,缺乏利用床旁超声(POCUS)评估客观瞳孔参数以预测患者GCS的文献。在这项前瞻性横断面研究中,急诊科招募了200例患者。纳入标准为年龄大于18岁且急性出现精神状态改变的患者。排除标准为部分眼球破裂或患有痴呆症的患者。患者在静息状态和光刺激后接受B型POCUS引导下的评估。使用Spearman等级相关系数、Kruskal-Wallis总体秩和检验以及受试者工作特征曲线下面积对瞳孔评估参数与GCS之间的关系进行统计分析。该研究包括200例患者(42例女性,158例男性),年龄和GCS的平均值(±标准差)分别为43.56±16.50岁和5.54±3.00。大多数无反应性瞳孔的GCS评分为3 - 8分(74例,97.37%)。瞳孔直径(PD)和PD变化与瞳孔对光刺激的反应性及GCS在统计学上具有显著一致性,PD的Spearman相关系数范围为0.28至0.33,PD变化的相关系数为 - 0.55至 - 0.50(p值<0.05)。PD变化率(PDVR)是光刺激时PD收缩幅度的百分比变化。PDVR>19.68%检测GCS>8的灵敏度为86.96%(95%CI:82.04 - 91.88%),特异度为64.97%(95%CI:58.00 - 71.94%)。POCUS测量的PD变化和PDVR与GCS>8具有显著相关性。该研究显示光刺激时PDVR检测GCS>8具有良好的灵敏度和较低的特异度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验