Al-Obaidi Sameer Z, Atem Folefac D, Stutzman Sonja E, Olson DaiWai M
School of Medicine, University of Texas Southwestern, Dallas, TX.
Department of Biostatistics and Data Science, University of Texas at Houston, Houston, TX.
Crit Care Explor. 2019 Oct 30;1(10):e0054. doi: 10.1097/CCE.0000000000000054. eCollection 2019 Oct.
In a diverse, multicenter population, to confirm or refute the conclusions that pupillary light reflex changes are associated with increased intracranial pressure.
Replication study.
Within the Establishing Normative Data for Pupillometer Assessments in Neuroscience Intensive Care registry there were 273 patients (16,221 pupillary observations) that included both intracranial pressure and pupillometry values.
To evaluate findings by the previous author, we explored for differences among measures of the pulmonary light reflex obtained from automated pupillometry with ICP values dichotomized as < 15 mm Hg (normal) versus ≥ 15 mm Hg (elevated). Analysis of t-test indicates statistically significant differences for all right and left mean pupilometer values, except right latency ( = 0.3000) and repeated measure mixed model ( = 0.0001). In the setting of increased intracranial pressure, mean pupilometer values were lower for both left and right eyes comparing to normal intracranial pressure, except right neurologic pupil index (3.98, 3.92; = 0.0300) and left latency (0.27, 0.25; < 0.0001).
Our findings confirm and extend those of McNett et al Worsening measures of the pupillary light reflex using automated pupillometry are associated with elevated intracranial pressure.
在一个多样化的多中心人群中,证实或反驳瞳孔光反射变化与颅内压升高相关的结论。
重复研究。
在神经重症监护瞳孔测量评估规范数据建立登记处中,有273名患者(16221次瞳孔观察),包括颅内压和瞳孔测量值。
为了评估前一位作者的研究结果,我们探讨了通过自动瞳孔测量获得的瞳孔光反射测量值之间的差异,将颅内压值分为<15 mmHg(正常)与≥15 mmHg(升高)。t检验分析表明,除右侧潜伏期(P = 0.3000)和重复测量混合模型(P = 0.0001)外,所有左右平均瞳孔测量值均有统计学显著差异。在颅内压升高的情况下,与正常颅内压相比,左右眼的平均瞳孔测量值均较低,但右侧神经瞳孔指数(3.98,3.92;P = 0.0300)和左侧潜伏期(0.27,0.25;P < 0.0001)除外。
我们的研究结果证实并扩展了McNett等人的研究结果 使用自动瞳孔测量法测量的瞳孔光反射恶化与颅内压升高有关。